View larger
MINI MCR-EX-IDS-I-I 2908805 PHOENIX CONTACT MINI Analog Signal Conditioner SIL 2
MINI MCR-EX-IDS-I-I
2908805
PHOENIX CONTACT
1 Pcs.
Automation > Isolation amplifier
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for hazardous area applications, the Phoenix Contact MINI MCR-EX-IDS-I-I is a MINI Analog Signal Conditioner SIL 2 that provides galvanic isolation for analog signals. Output signal conditioners are installed in industrial instrumentation loops to safely transmit process values while separating intrinsically safe and non-intrinsically safe circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Output signal conditioner
- Product family: MINI Analog Pro
- Configuration: DIP switches
- Data management status Article revision: 03
- Functionality Configuration: DIP switches
- Signal transmission behavior: In = Out
- Step response (10-90%): ≤ 10 ms
- Maximum temperature coefficient: ≤ 0.01 %
- Maximum transmission error: 0.1 %
- Electrical isolation Overvoltage category: II (≤ 5000 m)
- Pollution degree: 2 (≤ 5000 m)
- Rated insulation voltage: 300 V rms
- Test voltage: 2.5 kV AC (50 Hz, 60 s)
- Insulation: Double/reinforced insulation
- Rated insulation voltage: 253 V rms
- Rated insulation voltage: 251 V rms
More info
▲| Product type | Output signal conditioner |
| Product family | MINI Analog Pro |
| Configuration | DIP switches |
| Data management status | |
| Article revision | 03 |
| Functionality | |
| Configuration | DIP switches |
| Signal transmission behavior | In = Out |
| Step response (10-90%) | ≤ 10 ms |
| Maximum temperature coefficient | ≤ 0.01 % |
| Maximum transmission error | 0.1 % |
| Electrical isolation | |
| Overvoltage category | II (≤ 5000 m) |
| Pollution degree | 2 (≤ 5000 m) |
| Electrical isolation Input/output/power supply IEC/EN 61010-1 | |
| Standards/regulations | IEC/EN 61010-1 |
| Rated insulation voltage | 300 Vrms |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| Insulation | Double/reinforced insulation |
| Electrical isolation Output/input, power supply IEC/EN 60079-11 | |
| Standards/regulations | IEC/EN 60079-11 |
| Rated insulation voltage | 253 Vrms |
| Electrical isolation Input/output/power supply IEC/EN 60079-7 | |
| Standards/regulations | IEC/EN 60079-7 |
| Rated insulation voltage | 251 Vrms |
| Supply | |
| Nominal supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Power consumption | ≤ 1.2 W |
| Signal: Current | |
| Number of inputs | 1 |
| Current input signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA (SIL) | |
| Input current | ≤ 30 mA |
| Voltage drop | < 3.5 V DC (20 mA) |
| Signal: Current | |
| Output description | intrinsically safe |
| Number of outputs | 1 |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA (SIL) | |
| Load/output load current output | ≤ 700 Ω (20 mA) |
| ≤ 630 Ω (21 mA) | |
| Output ripple | 20 mV (rms) |
| Non-load voltage | ≤ 27 V DC |
| Short-circuit-proof | yes |
| Line fault detection | > 10 kΩ (Line break) |
| < 50 Ω (Short circuit) | |
| Connection method | Screw connection |
| Stripping length | 10 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² (with ferrule) |
| 0.14 mm² ... 2.5 mm² (without ferrule) | |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 (flexible) |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Ex installation (EPL) | Gc |
| Div. 2 | |
| Ex i circuits (EPL) | Ga |
| Da | |
| Ma | |
| Div. 1 | |
| Safety data | |
| Max. internal inductance Li | negligible |
| Max. internal capacitance Ci | 7 nF |
| Max. output voltage Uo | 26.4 V |
| Max. output current Io | 98 mA |
| Max. output power Po | 647 mW |
| Safety-related maximum voltage Um | 253 V AC |
| 125 V DC | |
| IIA/I (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 10 mH / 2.48 µF |
| IIB/III (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 4 mH / 730 nF |
| IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 2 mH / 89 nF |
| IIA/I (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 10 mH / 493 nF, 1 mH / 553 nF, 500 µH / 653 nF, 200 µH / 833 nF, 100 µH / 993 nF |
| IIB/III (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 4 mH / 303 nF, 1 mH / 383 nF, 500 µH / 463 nF, 200 µH / 613 nF, 100 µH / 733 nF |
| IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 1.4 mH / 42 nF, 1 mH / 49 nF, 500 µH / 66 nF, 200 µH / 89 nF |
| Data communication (bypass) | |
| Protocols supported | HART-transparent |
| Status display | Green LED (supply voltage) |
| Width | 6.2 mm |
| Height | 109.81 mm |
| Depth | 119.2 mm |
| Color | gray (RAL 7042) |
| Housing material | PBT |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 70 °C (Any mounting position) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (at 25 °C, non-condensing) |
| Shock (operation) | 15g (DIN EN 60068-2-27) |
| Vibration (operation) | 5g (DIN EN 60068-2-6) |
| Altitude range (IEC/EN 61010-1) | |
| Height range | > 2000 m ... 3000 m |
| Ambient temperature (operation) | -40 °C ... 63 °C |
| Rated insulation voltage | 300 Vrms(Input/output/power supply) |
| Insulation | Double/reinforced insulation |
| Altitude range (IEC/EN 61010-1) | |
| Height range | > 3000 m ... 4000 m |
| Ambient temperature (operation) | -40 °C ... 56 °C |
| Rated insulation voltage | 300 Vrms(Input/output/power supply) |
| Insulation | Double/reinforced insulation |
| Altitude range (IEC/EN 61010-1) | |
| Height range | > 4000 m ... 5000 m |
| Ambient temperature (operation) | -40 °C ... 49 °C |
| Rated insulation voltage | 150 Vrms(Input/output/power supply) |
| Insulation | Double/reinforced insulation |
| Altitude range (IEC/EN 60079-11) | |
| Height range | > 2000 m ... 3000 m |
| Ambient temperature (operation) | -40 °C ... 63 °C |
| Safety-related maximum voltage Um | 121 V AC |
| 110 V DC | |
| Rated insulation voltage | 150 Vrms(Output/input, power supply) |
| Altitude range (IEC/EN 60079-11) | |
| Height range | > 3000 m ... 4000 m |
| Ambient temperature (operation) | -40 °C ... 56 °C |
| Safety-related maximum voltage Um | 33 V AC/DC |
| Rated insulation voltage | 60 Vrms(Output/input, power supply) |
| Altitude range (IEC/EN 60079-11) | |
| Height range | > 4000 m ... 5000 m |
| Ambient temperature (operation) | -40 °C ... 49 °C |
| Safety-related maximum voltage Um | 33 V AC/DC |
| Rated insulation voltage | 60 Vrms(Output/input, power supply) |
| Altitude range (IEC/EN 60079-7) | |
| Height range | > 2000 m ... 3000 m |
| Ambient temperature (operation) | -40 °C ... 63 °C |
| Rated insulation voltage | 162 Vrms(Input/output/power supply) |
| Altitude range (IEC/EN 60079-7) | |
| Height range | > 3000 m ... 4000 m |
| Ambient temperature (operation) | -40 °C ... 56 °C |
| Rated insulation voltage | 60 Vrms(Input/output/power supply) |
| Altitude range (IEC/EN 60079-7) | |
| Height range | > 4000 m ... 5000 m |
| Ambient temperature (operation) | -40 °C ... 49 °C |
| Rated insulation voltage | 60 Vrms(Input/output/power supply) |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II (1) G [Ex ia Ga] IIC |
| II (1) D [Ex ia Da] IIIC | |
| II 3 (1) G Ex ec [ia Ga] IIC T4 Gc | |
| I (M1) [Ex ia Ma] I | |
| Certificate | BVS 23 ATEX 006 X |
| IECEx | |
| Identification | [Ex ia Ga] IIC |
| [Ex ia Da] IIIC | |
| Ex ec [ia Ga] IIC T4 Gc | |
| [Ex ia Ma] I | |
| Certificate | IECEx BVS 23.0003X |
| UL, USA/Canada | |
| Identification | UL 61010-2-201 |
| Safety Integrity Level (SIL, IEC 61508) | |
| Identification | 3 |
| Note | Single-channel |
| Electromagnetic compatibility | Tested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21 |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Noise immunity | EN 61000-6-2 |
| EN 61326-3-2 | |
| Noise emission | EN 61000-6-4 |
| Mounting type | DIN rail mounting |
| Mounting position | any |