View larger
MCR-SL-S- 16-SP- 24 2864464 PHOENIX CONTACT Current monitoring
MCR-SL-S-16-SP-24
2864464
PHOENIX CONTACT
1 Pcs.
Automation > Current value transformer
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact MCR-SL-S-16-SP-24 is a current monitoring unit built to track electrical current thresholds and protect machinery from overcurrent conditions. Industrial automation systems deploy these monitoring devices to safeguard motors and generators against unexpected load spikes. Specific pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Initial value measuring range current (EF008198): 0 A
- End value measuring range current (EF008266): 16 A
- Frequency rated current (EF005737): 50 Hz
- Integrated configuration function (EF003064): No
- With switching output (EF005225): No
More info
▲Key Commercial Data
| Orderkey | 2864464 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 249 (C-5-2017) |
| GTIN | 4017918904456 |
| Weight per Piece (excluding packing) | 139.200 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 65 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C (non-condensing) |
| Maximum altitude | ≤ 2000 m |
Input data
| Input | Current measuring input |
|---|---|
| Input current range | 0 A AC ... 16 A |
| Impulse form | Sine |
| Overload capacity | 2 x IN (continuous) |
| Nominal frequency fN | 50 Hz |
| 60 Hz | |
| Frequency measuring range | 45 Hz ... 65 Hz |
Switching output
| Output name | Relay output |
|---|---|
| Contact type | 1 PDT |
| Contact material | AgSnO, hard gold-plated |
| Maximum switching voltage | 30 V AC |
| 36 V DC | |
| 250 V AC (when the gold layer is destroyed) | |
| Limiting continuous current | 50 mA (for gold layer, 30 V AC/ 36 V DC) |
| 2 A (in case of a destroyed gold layer, 250 V AC) | |
| Setting range of the response delay | typ. 0.1 s ... 10 s (Adjustable using a potentiometer) |
Connection data
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Stripping length | 8 mm |
| Screw thread | M3 |
General
| Maximum temperature coefficient | < 0.02 %/K |
|---|---|
| Step response (10-90%) | 40 ms |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Rated insulation voltage | 300 V AC (to earth) |
| Test voltage input/output | 3.5 kV (50 Hz, 1 min.) |
| Test voltage input/power supply | 3.5 kV (50 Hz, 1 min.) |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Color | green |
| Housing material | Polyamide PA non-reinforced |
| Mounting position | any |
| Conformance | CE-compliant |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC directive |
|---|---|
| Noise emission | EN 61000-6-4 |
| Connection in acc. with standard | CUL |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |