View larger
UCS SW 195-H 9005 2203382 PHOENIX CONTACT Side panel
UCS SW 195-H 9005
2203382
PHOENIX CONTACT
10 Pcs.
Automation > Extruded profile modular housing
Housing (HS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact UCS SW 195-H 9005 is a side panel utilized in modular electronic enclosure assemblies to enclose internal printed circuit boards and electronic components safely. Enclosure accessories of this category help configure custom housing dimensions for specialized automation systems, protecting sensitive circuitry from dust and physical contact in control rooms. Such panels provide structural integrity and a clean exterior finish for complex control hardware.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of enclosure (EF003086): Open
- Housing connectable (EF003088): No
- Suitable for rail mounting (EF003972): No
- Wall mounting possible (EF003973): No
- With integrated PCB-mounting connection system (EF003087): No
- Colour (EF000007): Black
- RAL-number (EF000116): 9005
- Width (EF000008): 166 mm
- Height (EF000040): 59.4 mm
- Depth (EF000049): 2 mm
More info
▲Key Commercial Data
| Orderkey | 2203382 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 10 pc |
| GTIN | 4055626427638 |
| Weight per Piece (excluding packing) | 23.000 g |
| Custom tariff number | 85389099 |
| Country of origin | DE (Germany) |
Material specifications
| Color (RAL) | black (9005) |
|---|---|
| Insulating material | PC |
| CTI according to IEC 60112 | 2 |
| Flammability rating according to UL 94 | V0 |
| Housing material | PC |
Ambient conditions
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 100 °C (depending on power dissipation) |
Mechanical strength/tumbling barrel
| Specification | IEC 60068-2-31:2008-05 |
|---|---|
| Height of fall | 50 cm |
| Number of drop cycles | 50 |
Thermostability (ball thrust test)
| Specification | IEC 60695-10-2:2014-02 |
|---|---|
| Temperature | 125 °C |
| Test duration | 1 h |
| Force | 20 N |
Test for assessing the risk of fire (glow wire)
| Specification | DIN EN 60695-2-11 (VDE 0471-2-11):2014-11 |
|---|---|
| Temperature | 850 °C |
| Time of exposure | 30 s |
Test for substances that would hinder coating with paint or varnish
| Result | Test passed |
|---|---|
| Specification | VW PV 3.10.7:2005-02 |