View larger
UM6M-TM (6X12) 0830926 PHOENIX CONTACT Marker for terminal blocks
UM6M-TM (6X12)
0830926
PHOENIX CONTACT
10 Pcs.
Automation > Labelling for terminal block
MS Material
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact UM6M-TM (6X12) 0830926 Marker for terminal blocks is designed to snap onto terminal blocks for clear circuit identification in complex machinery and distribution panels. Proper labeling ensures that maintenance teams can trace connections quickly and maintain compliance with safety standards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Terminal marking
- Area of application: ABB
- Pitch: 6 mm
- Type: high
- Data management status Article revision: 00
- Marking Number of individual labels: 20
- Number of individual labels per row: 10
- Number of marker strips: 2
- Width: 6 mm
- Text field width: 6.00 mm
- Text field height: 12.00 mm
- Length: 12 mm
- Pitch: 6 mm
- RoHS compliant: yes
- Color: white (RAL 9010)
- Material: PC
More info
▲| Product type | Terminal marking |
| Area of application | ABB |
| Pitch | 6 mm |
| Type | high |
| Data management status | |
| Article revision | 00 |
| Marking | |
| Number of individual labels | 20 |
| Number of individual labels per row | 10 |
| Number of marker strips | 2 |
| Width | 6 mm |
| Text field width | 6.00 mm |
| Text field height | 12.00 mm |
| Length | 12 mm |
| Pitch | 6 mm |
| RoHS compliant | yes |
| Color | white (RAL 9010) |
| Material | PC |
| Flammability rating according to UL 94 | V2 |
| Components | free from silicone, halogen, and cadmium |
| Test for substances that would hinder coating with paint or varnish | |
| Result | Test passed |
| UV resistance | |
| Specification | ISO 4892-2:2013-03 (following) |
| Result | Test passed |
| Test duration | 96 h |
| Wipe resistance of inscriptions | |
| Specification | IEC 61010-1:2010-06 |
| DIN EN 62208 (VDE 0660-511):2012-06 (in parts) | |
| Isopropyl [CAS No. 67-63-0] | Test passed |
| n-Hexane [CAS No. 110-54-3] | Test passed |
| Water + Petroleum ether [CAS No. 64742-82-1] | Test passed |
| Testing in a condensation changing climate in the presence of sulfur dioxide | |
| Specification | DIN 50018:2013-05 |
| Result | Test passed |
| Climate level | AHT 1.0 S |
| Cycles | 2 |
| Salt spray test | |
| Specification | DIN EN 60068-2-11:2000-02 |
| Result | Test passed |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 120 °C |
| Recommended ambient temperature (storage/transport) | 23 °C |
| Recommended humidity (storage/transport) | 50 % |
| Wipe resistance | DIN EN 61010-1 (VDE 0411-1) |
| Mounting type | latching |