View larger
Images are for illustrative purposes only. Please refer to data sheet for details
MACX MCR-TS-I-OLP-SP 2908664 PHOENIX CONTACT Temperature measuring transducer
MACX MCR-TS-I-OLP-SP
2908664
PHOENIX CONTACT
1 Pcs.
Temperature measuring transducer
Output loop-fed temperature converter to transmit up to 2 sensor signals from RTD and CT sensors, as well as resistance and voltage transmitters via 4 mA... 20 mA. HART, Standard Configuration, Safety Integrity Level (SIL, IEC61508): 2, Systematic Capability: 3, Push-in Connection
Automation > Temperature transformer
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact MACX MCR-TS-I-OLP-SP temperature measuring transducer is engineered to accurately capture temperature measurements and output loop-powered analog signals for automated industrial systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Measuring range (EF001836): -250 °C
- Analogue output 0 mA ... 20 mA (EF006808): No
- Analogue output 4 mA ... 20 mA (EF006810): Yes
- Analogue output 0 V ... 2 V (EF009886): No
- Analogue output 0 V ... 5 V (EF009887): No
- Analogue output 0 V ... 10 V (EF006807): No
- Analogue output 2 V ... 10 V (EF009888): No
- With switching output (EF005225): No
- Modular version (EF001126): Yes
- Integrated configuration function (EF003064): No
- Ambient temperature (EF002386): 85 °C
- Weight (EF000167): 0.169 kg
More info
▲Key Commercial Data
| Orderkey | 2908664 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 194 (C-5-2017) |
| GTIN | 4055626355443 |
| Weight per Piece (excluding packing) | 169.000 g |
| Custom tariff number | 85437090 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 85 °C |
|---|---|
| -40 °C ... 70 °C (SIL active) | |
| Ambient temperature (storage/transport) | -40 °C ... 100 °C |
| Maximum altitude | ≤ 4000 m (Above sea level) |
Input data
| Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
|---|---|
| Sensor types that can be used (TC) | A, B, C, D, E, J, K, L, N, R, S, T, U |
| Linear resistance measuring range | 10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω) |
| Temperature measuring range | -250 °C ... 2500 °C (Range depending on the sensor type) |
| -200 °C ... 850 °C (Pt 100) |
Output data
| Configurable/programmable | no |
|---|---|
| Current output signal | 4 mA ... 20 mA |
| 20 mA ... 4 mA | |
| Max. output current | 23 mA |
Connection data
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Stripping length | 8 mm |
General
| Overvoltage category | II |
|---|---|
| Degree of pollution | 2 |
| Conformance | CE-compliant |
| ATEX | II 3G Ex nA IIC T6...T4 Gc |
| UL, USA/Canada | UL 61010 Recognized |
| FM approval | NI, Class I, Div. 2, Groups A, B, C, D |
| CSA | NI / Class I / Div. 2 / ABCD T6/T5/T4 |
Standards and Regulations
| Conformance | CE-compliant |
|---|---|
| ATEX | II 3G Ex nA IIC T6...T4 Gc |
| UL, USA/Canada | UL 61010 Recognized |
| FM approval | NI, Class I, Div. 2, Groups A, B, C, D |
| CSA | NI / Class I / Div. 2 / ABCD T6/T5/T4 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |