View larger
MACX MCR-SL-I-I-ILP 2905278 PHOENIX CONTACT Loop-powered isolators
MACX MCR-SL-I-I-ILP
2905278
PHOENIX CONTACT
1 Pcs.
Automation > Isolation amplifier
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A MACX MCR-SL-I-I-ILP Loop-powered isolators by Phoenix Contact is a signal conditioning component designed to safely isolate analog current loops and prevent ground loops in industrial measurement chains. Signal conditioners are deployed in automation panels to protect sensitive control electronics and ensure accurate signal transmission across complex networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Signal conditioner
- Product family: MACX Analog
- No. of channels: 1
- Type: Signal conditioners with SIL functional safety
- Data management status Article revision: 04
- Insulation characteristics Overvoltage category: II
- Pollution degree: 2
- Electrical isolation: 2-way isolation
- Signal transmission behavior: In = Out
- Maximum temperature coefficient: ≤ 0.002 %/K (of measured value / 100 Ω load)
- Transmission error, typical: 0.08 % (of final value)
- Test voltage: 2.5 kV AC (50 Hz, 60 s)
- Insulation: Safe isolation in accordance with IEC/EN 61010-1
- Supply Supply voltage range: loop-powered, no external supply necessary
- Signal: Current
- Number of inputs: 1
- Configurable/programmable: no
More info
▲| Product type | Signal conditioner |
| Product family | MACX Analog |
| No. of channels | 1 |
| Type | Signal conditioners with SIL functional safety |
| Data management status | |
| Article revision | 04 |
| Insulation characteristics | |
| Overvoltage category | II |
| Pollution degree | 2 |
| Electrical isolation | 2-way isolation |
| Signal transmission behavior | In = Out |
| Maximum temperature coefficient | ≤ 0.002 %/K (of measured value / 100 Ω load) |
| Transmission error, typical | 0.08 % (of final value) |
| Electrical isolation Input/output/power supply | |
| Rated insulation voltage | 300 Vrms |
| Test voltage | 2.5 kV AC (50 Hz, 60 s) |
| Insulation | Safe isolation in accordance with IEC/EN 61010-1 |
| Supply | |
| Supply voltage range | loop-powered, no external supply necessary |
| Signal: Current | |
| Number of inputs | 1 |
| Configurable/programmable | no |
| Max. voltage input signal | < 30.5 V |
| Current input signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| Input voltage limitation | 30.5 V |
| Voltage dissipation | 2.9 V (I = 20 mA) |
| Step response (10-90%) | 5 ms (500 Ω load) |
| Additional error, load-dependent | 0.022 % (of measured value / 100 Ω load) |
| Response current | approx. 50 µA |
| Signal: Current | |
| Number of outputs | 1 |
| Configurable/programmable | no |
| Max. voltage output signal | 27.5 V |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| Load/output load current output | ≤ 1375 Ω (I = 20 mA) |
| Residual ripple | < 10 mVrms(500 Ω load) |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Test socket | |
| Max. diameter | 2.3 mm |
| Ex installation (EPL) | Gc |
| Div. 2 |
| Dimensional drawing | |
| Width | 12.5 mm |
| Height | 112.5 mm |
| Depth | 113.7 mm |
| Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 (Housing) |
| Housing material | PA 6.6-FR |
| Ambient conditions | |
| Degree of protection | IP20 (not assessed by UL) |
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | < 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| CE | |
| Certificate | CE-compliant |
| Note | and EN 61326-1 |
| ATEX | |
| Identification | II 3 G Ex nA IIC T4 Gc X |
| UKCA Ex (UKEX) | |
| Identification | II 3 G Ex nA IIC T4 Gc X |
| Certificate | PxCIF21UKEX2905278X |
| UL, USA/Canada | |
| Identification | UL 61010 Listed |
| Class I, Div. 2, Groups A, B, C, D T4 | |
| Class I, Zone 2, Group IIC T4 | |
| Safety Integrity Level (SIL, IEC 61508) | |
| Identification | 3 |
| Certificate | 968/FSP 1200.01/21 |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise immunity | EN 61326-1 |
| Noise emission | EN 61000-6-4 |
| Electrical isolation | 2-way isolation |
| Mounting type | DIN rail mounting |