View larger
MACX MCR-EX-RTD-I 1050222 PHOENIX CONTACT Ex i temperature transducer: converts signals from resistance temp..
MACX MCR-EX-RTD-I
1050222
PHOENIX CONTACT
1 Pcs.
Automation > Temperature transformer
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact MACX MCR-EX-RTD-I is an Ex i temperature transducer engineered to convert signals from resistance temperature detectors while offering intrinsic safety for explosive atmospheres. Industrial automation engineers utilize such transducers to maintain measurement accuracy and protect downstream control hardware from hazardous electrical disturbances.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Analogue output 0 mA ... 20 mA (EF006808): No
- Analogue output 4 mA ... 20 mA (EF006810): Yes
- Analogue output 0 V ... 2 V (EF009886): No
- Analogue output 0 V ... 5 V (EF009887): No
- Analogue output 0 V ... 10 V (EF006807): No
- Analogue output 2 V ... 10 V (EF009888): No
- With switching output (EF005225): No
- EMC-version (EF001062): Yes
- Ambient temperature (EF002386): 70 °C
- Weight (EF000167): 0.13 kg
More info
▲Key Commercial Data
| Orderkey | 1050222 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 146 (C-5-2019) |
| GTIN | 4055626666075 |
| Weight per Piece (excluding packing) | 0.000 g |
| Custom tariff number | 85437090 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 70 °C (Any mounting position) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Degree of protection | IP20 |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Input data
| Input | Intrinsically safe |
|---|---|
| Sensor types (RTD) that can be used | Sensors (2-, 3-, 4-wire) |
| Temperature measuring range | -200 °C ... 850 °C (Range depending on the sensor type) |
| Input signal range | 0 Ω ... 50 kΩ |
| Potentiometer resistance range | 0 Ω ... 50 kΩ |
| Cable resistance | ≤ 50 Ω per cable |
| Sensor input current | 10 µA ... 210 µA (up to 2 x 210 µA for 3-conductor) |
| Measuring range span | ≥ 50 K |
Output data
| Signal output | Current output |
|---|---|
| Configurable/programmable | Yes |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA (SIL) | |
| Load/output load current output | ≤ 600 Ω |
| Output ripple (current) | < 15 µAPP |
| Behavior in the event of a sensor error | As per NE 43 or can be freely defined |
Power supply
| Nominal supply voltage | 24 V DC |
|---|---|
| Supply voltage range | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
| Power dissipation | ≤ 0.76 W |
| Power consumption | ≤ 1 W |
Connection data
| Connection method | Screw connection |
|---|---|
| Stripping length | 7 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
General
| No. of channels | 1 |
|---|---|
| Transmission error, typical | 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA) |
| Temperature coefficient, typical | 0.01 %/K |
| Step response (0–99%) | typ. 1 s |
| ≤ 1.7 s | |
| Alignment zero | ± 5 % |
| Alignment span | ± 5 % |
| Status display | Green LED (supply voltage, PWR) |
| Red LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR) | |
| Red LED, flashing 1.2 Hz (service operation, ERR) | |
| Red LED, permanently on (module error, ERR) | |
| Electromagnetic compatibility | Conformance with EMC directive |
| Interference emission | EN 61000-6-4 |
| Housing material | PA 6.6-FR |
| Color | gray |
| Designation | Input/output/power supply |
| Electrical isolation | 300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1)) |
| 2.5 kV (50 Hz, 1 min., test voltage) | |
| Designation | Input/output |
| Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
| Designation | Input/power supply |
| Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
| Conformance | CE-compliant, additionally EN 61326 |
| ATEX | I (M1) [Ex ia Ma] I |
| II (1) G [Ex ia Ga] IIC | |
| II (1) D [Ex ia Da] IIIC | |
| II 3(1) G Ex ec ic [ia Ga] IIC T4 Gc | |
| IECEx | [Ex ia Ma] I |
| [Ex ia Ga] IIC | |
| [Ex ia Da] IIIC | |
| Ex ec ic [ia Ga] IIC T4 Gc | |
| Ex ec ic IIC T4 Gc | |
| SIL | 2 |
Safety data
| Max. internal capacitance Ci | 44 nF |
|---|---|
| Max. output voltage Uo | 6 V |
| Max. output current Io | 16.6 mA (RTD in 4-wire technology) |
| Max. output power Po | 25.2 mW (Linear) |
| Group | IIC/IIB/IIA |
| Max. external inductivity Lo | 100 mH |
| Max. external capacitance Co | 40 µF |
| Safety-related maximum voltage Um | 253 V AC (125 V DC, Zone 2: 3.1, 3.2 = 30 V DC) |
| Input voltage Ui | 7 V |
| Input current Ii | 100 mA |
| Input power Pi | 550 mW |
| Max. internal capacitance Ci | 47 µF |
| Max. output voltage Uo | 3.5 V |
| Max. output current Io | 400 mA |
| Max. output power Po | 350 mW |
| Group | IIC |
| Max. external inductivity Lo | 20 µH |
| Max. external capacitance Co | 2 µF |
EMC data
| Designation | Electromagnetic RF field |
|---|---|
| Standards/regulations | EN 61000-4-3 |
| Typical deviation from the measuring range final value | 1 % |
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
| Typical deviation from the measuring range final value | 1 % |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Typical deviation from the measuring range final value | 1 % |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC directive |
|---|---|
| Noise emission | EN 61000-6-4 |
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
| EN 61000-4-4 | |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Conformance | CE-compliant, additionally EN 61326 |
| ATEX | I (M1) [Ex ia Ma] I |
| II (1) G [Ex ia Ga] IIC | |
| II (1) D [Ex ia Da] IIIC | |
| II 3(1) G Ex ec ic [ia Ga] IIC T4 Gc | |
| IECEx | [Ex ia Ma] I |
| [Ex ia Ga] IIC | |
| [Ex ia Da] IIIC | |
| Ex ec ic [ia Ga] IIC T4 Gc | |
| Ex ec ic IIC T4 Gc | |
| DNV GL-Temperature | B |
| DNV GL-Humidity | B |
| DNV GL-Vibration | A |
| DNV GL-EMC | B |
| DNV GL-Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Group | IIC/IIB/IIA |
| IIC |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
| eCl@ss 4.0 | 27210120 |
|---|---|
| eCl@ss 4.1 | 27210120 |
| eCl@ss 5.0 | 27210120 |
| eCl@ss 5.1 | 27210120 |
| eCl@ss 6.0 | 27210120 |
| eCl@ss 7.0 | 27210120 |
| eCl@ss 8.0 | 27200206 |
| eCl@ss 9.0 | 27210129 |
ETIM
| ETIM 2.0 | EC001446 |
|---|---|
| ETIM 3.0 | EC001446 |
| ETIM 4.0 | EC001446 |
| ETIM 5.0 | EC001446 |
| ETIM 6.0 | EC002919 |
| ETIM 7.0 | EC002919 |
UNSPSC
| UNSPSC 6.01 | 30211506 |
|---|---|
| UNSPSC 7.0901 | 39121008 |
| UNSPSC 11 | 39121008 |
| UNSPSC 12.01 | 39121008 |
| UNSPSC 13.2 | 41112105 |
| UNSPSC 18.0 | 41112105 |
| UNSPSC 19.0 | 41112105 |
| UNSPSC 20.0 | 41112105 |
| UNSPSC 21.0 | 41112105 |