PHOENIX CONTACT MACX MCR-EX-AP-RTD-RTD MACX MCR-EX-AP-RTD-RTD 1291894 PHOENIX CONTACT Ex i-resistance insulator transformer is used for intrinsical.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MACX MCR-EX-AP-RTD-RTD 1291894 PHOENIX CONTACT Ex i-resistance insulator transformer is used for intrinsical..

MACX MCR-EX-AP-RTD-RTD

1291894

PHOENIX CONTACT

1 Pcs.

Ex i-resistance insulator transformer is used for intrinsically safe service of Pt 100 heat resistors in the technology of 2, 3 or 4 conductors and resistance transmitters. The measured values at the Ex i input are transmitted 1:1 to the non-Ex i output. Standard configuration, 3-way separation, Screw connection Ex i, Resistance Isolating Transformer is used for the intrinsically safe service of Pt 100 resistance thermometers in the technology of 2, 3 or 4 resistance conductors and transmitters. The measured values at the input Ex i are transmitted 1:1 to the output at non-Ex i. 3-Way Separation, Screw Connection Ex i-Resistance isolator for intrinsically safe operation of Pt 100 resistance thermometers in 2, 3, or 4-conductor technology and resistance-type sensors. The values measured at the Ex i input are transmitted 1:1 to the non Ex i output. Standard configuration, 3-way isolation, Screw connection

Automation > Temperature transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Ex i-resistance insulator transformer, represented by the Phoenix Contact MACX MCR-EX-AP-RTD-RTD, is deployed in hazardous industrial locations to safely transfer intrinsically safe temperature measurement signals from sensitive field devices to safe-area control systems. By providing robust galvanic isolation, it prevents dangerous energy transfer into explosive atmospheres. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • General: Accuracy, typically specified as a percentage of the basic measuring range at U N , 23°C:
  • General: Sensor set via DIP switches:
  • General: 2-conductor comparison set via DIP switch ADJ:
  • Product type: Temperature transmitter
  • Product family: MACX Analog
  • No. of channels: 1
  • Electrical isolation: 3-way isolation
  • Signal transmission behavior: In = Out
  • Temperature coefficient, typical: ≤ 0.1 % (10 K)
  • Reverse polarity protection: yes
  • Rated insulation voltage: 375 V PP
  • Electrical isolation Output 1/output 2 Test voltage: 350 V (50 Hz, 60 s)

More info

▲
Technical data

Notes
GeneralAccuracy, typically specified as a percentage of the basic measuring range at UN, 23°C
GeneralInstallation conditions influence the ambient temperature.
Please refer to the “Control cabinet installation instructions”.
GeneralSensor set via DIP switches
General2-conductor comparison set via DIP switch ADJ

Product properties
Product typeTemperature transmitter
Product familyMACX Analog
No. of channels1

Electrical properties
No. of channels1
Electrical isolation3-way isolation
Signal transmission behaviorIn = Out
Temperature coefficient, typical≤ 0.1 % (10 K)
Reverse polarity protectionyes
Electrical isolation Input/output IEC/EN 60079-11
Standards/regulationsIEC/EN 60079-11
Rated insulation voltage375 VPP
Electrical isolation Input/power supply IEC/EN 60079-11
Standards/regulationsIEC/EN 60079-11
Rated insulation voltage375 VPP
Electrical isolation Input/error message output IEC/EN 60079-11
Standards/regulationsIEC/EN 60079-11
Rated insulation voltage375 VPP
Electrical isolation Input/configuration interface IEC/EN 60079-11
Standards/regulationsIEC/EN 60079-11
Rated insulation voltage375 VPP
Electrical isolation Output 1/output 2
Test voltage350 V (50 Hz, 60 s)
Electrical isolation Output/supply
Test voltage350 V (50 Hz, 60 s)
Electrical isolation Output/configuration interface
Test voltage350 V (50 Hz, 60 s)
Electrical isolation Output/supply/error message output
Test voltage350 V (50 Hz, 60 s)
Supply
Nominal supply voltage24 V DC
Supply voltage range18 V ... 31.2 V
Power dissipation≤ 600 mW
Power consumption≤ 650 mW

Input data
Measurement
Description of the inputIntrinsically safe
Sensor types (RTD) that can be usedPt 100
Connection technology2-, 3-, 4-conductor
Linear resistance measuring range18 Ω ... 391 Ω (Pt 100)
Max. permissible overall conductor resistance≤ 50 Ω (per wire, 2-conductor circuit)
≤ 100 Ω (per wire, 3-, 4-conductor circuit)

Output data
Analog: Resistance thermometer
Output signal Voltage2 V DC (Nominal voltage)
Output signal Current5 mA (Nominal current)
Output signal Resistance400 Ω
Output signal Resistance range18 Ω ... 391 Ω (Pt 100)
Settling time< 10 ms (10% ... 90%, multiplexer mode)
Setting range< 1 s (Input/output)
Sensor input current200 µA ... 5 mA
Connection technology2-, 3-, 4-conductor
Signal: Error message output
Maximum switching voltage30 V
Max. switching current100 mA

Connection data
Cross section AWG(converted acc. to IEC)
Connection methodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

Ex data
Ex installation (EPL)Gc
Ex i circuits (EPL)Ga
Da
Ma
Safety data
Max. internal inductance Linegligible
Max. internal capacitance Cinegligible
Max. output voltage Uo6.5 V
Max. output current Io16.5 mA
Max. output power Po27 mW
Safety-related maximum voltage Um253 V AC
IIA (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co900 mH / 1000 µF
IIB/IIIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co450 mH / 570 µF
IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co120 mH / 25 µF
I (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co1000 mH / 1000 µF
IIB/IIIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co100 mH / 5.3 µF, 20 mH / 6.9 µF, 2 mH / 11 µF, 0.5 mH / 15 µF
IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co50 mH / 1.1 µF, 5 mH / 1.7 µF, 1 mH / 2.3 µF, 0.2 mH / 3.4 µF

Signaling
Status displayGreen LED (supply voltage)
Red LED (line errors)

Dimensions
Dimensional drawing
Width17.5 mm
Height112.5 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications
Flammability rating according to UL 94V0
Housing materialPolyamide (PA 6.6)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20 (Terminal blocks)
IP30 (Housing)
Ambient temperature (operation)-20 °C ... 70 °C (Stand-alone device: any mounting position)
-20 °C ... 60 °C (Group assembly: vertical DIN rail without circulating air)
-20 °C ... 65 °C (Group assembly: vertical DIN rail with circulating air)
-20 °C ... 65 °C (Group assembly: horizontal DIN rail without circulating air)
-20 °C ... 70 °C (Group assembly: horizontal DIN rail with circulating air)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operation)≤ 95 % (non-condensing)

Approvals
ATEX
Identification II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
IECEx
Identification[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Ma] I

EMC data
Electromagnetic compatibilityTested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21

Standards and regulations
Electrical isolation3-way isolation

Mounting
Mounting typeNS 35/15, NS 35/7,5
Mounting positionvertical, horizontal

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.