View larger
Images are for illustrative purposes only. Please refer to data sheet for details
MACX MCR-EX-AP-RPSS-I-IR-SP 1290776 PHOENIX CONTACT Ex i-Input and power signal conditioner with 2 limit val..
MACX MCR-EX-AP-RPSS-I-IR-SP
1290776
PHOENIX CONTACT
1 Pcs.
Ex i-Input and power signal conditioner with 2 limit value relays, powers 2, 3 and 4 conductor measurement transducers, transmits 1:1 active or passive input signals of 0 mA/4 mA... 20 mA and has 2 configurable limit value outputs. With HART transparency, Standard configuration, 4-way separation, Safety Integrity Level (SIL, IEC 61508): 2, Push-in connection
Ex i, Input and Power Signal Conditioner with 2 Limit Value Relays, Feeds 2 or 3 Conductor Measurement Transducers, Transmits 1:1 0 mA / 4 mA Input Signals... 20 mA active or passive and has 2 configurable limit value outputs. 4-way separation,
Ex i-Feed and input signal conditioner with 2 limit value relays, feeds 2-, 3-, and 4-conductor measuring transducer, transmits 1:1 passive or active 0 mA/4 mA ... 20 mA input signals and has 2 configurable limit value outputs. HART-transparent, Standard configuration, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, Push-in connection
Automation > Isolation amplifier
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact MACX MCR-EX-AP-RPSS-I-IR-SP signal conditioner serves as an intrinsically safe repeater power supply with integrated limit value monitoring for hazardous area process instrumentation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General: Output behavior = input signal
- Product type: Repeater power supplies
- Product family: MACX Analog
- No. of channels: 1
- No. of channels: 1
- Electrical isolation: 4-way isolation
- Linearity error: ≤ 0.1 %
- Typical offset error: ≤ 0.1 %
- Signal transmission behavior: In = Out
- Temperature coefficient, typical: ≤ 0.1 % (10 K)
- Reverse polarity protection: yes
- Rated insulation voltage: 375 V PP
- Rated insulation voltage: 375 V PP
- Rated insulation voltage: 375 V PP
- Rated insulation voltage: 375 V PP
- Electrical isolation Output/supply Test voltage: 350 V (50 Hz, 60 s)
More info
▲Technical data
Notes
| General | Installation conditions influence the ambient temperature. Please refer to the “Control cabinet installation instructions”. |
| General | Output behavior = input signal |
Product properties
| Product type | Repeater power supplies |
| Product family | MACX Analog |
| No. of channels | 1 |
Electrical properties
| No. of channels | 1 |
| Electrical isolation | 4-way isolation |
| Linearity error | ≤ 0.1 % |
| Typical offset error | ≤ 0.1 % |
| Signal transmission behavior | In = Out |
| Temperature coefficient, typical | ≤ 0.1 % (10 K) |
| Reverse polarity protection | yes |
| Electrical isolation Input/output IEC/EN 60079-11 | |
| Standards/regulations | IEC/EN 60079-11 |
| Rated insulation voltage | 375 VPP |
| Electrical isolation Input/power supply IEC/EN 60079-11 | |
| Standards/regulations | IEC/EN 60079-11 |
| Rated insulation voltage | 375 VPP |
| Electrical isolation Input/error message output IEC/EN 60079-11 | |
| Standards/regulations | IEC/EN 60079-11 |
| Rated insulation voltage | 375 VPP |
| Electrical isolation Input/limit value contact IEC/EN 60079-11 | |
| Standards/regulations | IEC/EN 60079-11 |
| Rated insulation voltage | 375 VPP |
| Electrical isolation Output/supply | |
| Test voltage | 350 V (50 Hz, 60 s) |
| Electrical isolation Output/limit value contact | |
| Test voltage | 350 V (50 Hz, 60 s) |
| Electrical isolation Output/supply/error message output | |
| Test voltage | 350 V (50 Hz, 60 s) |
| Supply | |
| Nominal supply voltage | 24 V DC |
| Supply voltage range | 18 V ... 31.2 V |
| Power dissipation | 1.5 W (RL250 Ω) |
| Power consumption | 2 W (20 mA) |
Input data
| Signal: Repeater power supply operation | |
| Description of the input | active and passive current input, intrinsically safe |
| Input signal | Current |
| Current input signal | 4 mA ... 20 mA (with HART) |
| 2 mA ... 22 mA (Function area) | |
| Short-circuit current | ≤ 35 mA |
| Line fault detection | < 3.6 mA (Line break) |
| > 21 mA (Short circuit) | |
| Non-load voltage | ≤ 26 V |
| Signal: Signal conditioner operation | |
| Description of the input | Passive current input, intrinsically safe |
| Current input signal | 4 mA ... 20 mA (with HART) |
| 2 mA ... 22 mA (Function area) | |
| Input resistance current input | > 250 Ω (for mA sources) |
| Input current | ≤ 50 mA (for mA sources) |
| Short-circuit current | ≤ 35 mA |
| Line fault detection | < 3.6 mA (Line break) |
| > 21 mA (Short circuit) | |
| Non-load voltage | ≤ 26 V |
Output data
| Signal: Error message output | |
| Maximum switching voltage | 30 V |
| Max. switching current | 100 mA |
| Switching: Relay | |
| Contact switching type | 2 N/O contacts |
| Max. switching current | ≤ 170 mA (Resistive load) |
| ≤ 500 mA (≤ 1 ms) | |
| Typical response time | < 80 ms |
| Typical turn-off time | < 100 ms |
| Signal: Repeater power supply operation | |
| Output description | Current output (active) |
| Current output signal | 4 mA ... 20 mA (with HART) |
| 2 mA ... 22 mA (Function area) | |
| Load | 0 Ω ... 600 Ω |
| Output ripple (current) | ≤ 40 µA (effective) |
| Signal: Signal conditioner operation | |
| Output description | Signal conditioner operation |
| Current output signal | 4 mA ... 20 mA (with HART) |
| 2 mA ... 22 mA (Function area) | |
| Load | 0 Ω ... 600 Ω |
| Output ripple (current) | ≤ 40 µA (effective) |
Connection data
| Cross section AWG | (converted acc. to IEC) |
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
Ex data
| Ex installation (EPL) | Gc |
| Ex i circuits (EPL) | Ga |
| Da | |
| Ma | |
| Safety data: Repeater power supply operation (2-conductor measuring transducer) | |
| Note | With connection of measuring transducers |
| Max. internal inductance Li | negligible |
| Max. internal capacitance Ci | negligible |
| Max. output voltage Uo | 27 V |
| Max. output current Io | 87.9 mA |
| Max. output power Po | 574 mW |
| Safety-related maximum voltage Um | 253 V AC |
| IIB/IIIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 14 mH / 705 nF |
| IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 2.3 mH / 90 nF |
| IIB/IIIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 10 mH / 290 nF, 1 mH / 380 nF, 0.2 mH / 600 nF |
| IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 1 mH / 56 nF, 0.5 mH / 72 nF, 0.2 mH / 90 nF |
| Safety data: Repeater power supply operation (3-conductor measuring transducer) | |
| Note | With connection of measuring transducers |
| Max. internal inductance Li | negligible |
| Max. internal capacitance Ci | negligible |
| Max. output voltage Uo | 27 V |
| Max. output current Io | 88.3 mA |
| Max. output power Po | 574 mW |
| Safety-related maximum voltage Um | 253 V AC |
| IIB/IIIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 14 mH / 705 nF |
| IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co | 2.3 mH / 90 nF |
| IIB/IIIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 10 mH / 290 nF, 1 mH / 380 nF, 0.2 mH / 600 nF |
| IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co | 1 mH / 56 nF, 0.5 mH / 72 nF, 0.2 mH / 90 nF |
| Safety data: Signal conditioner operation | |
| Note | With connection of power sources |
| Input voltage Ui | 30 V |
| Input current Ii | 100 mA |
| Max. internal inductance Li | negligible |
| Max. internal capacitance Ci | negligible |
| Max. output voltage Uo | 4.1 V |
| Max. output current Io | 0 mA |
| Max. output power Po | 0 mW |
Interfaces
| Data communication (bypass) | |
| Protocols supported | HART-transparent |
| Frequency measuring range | 0.5 kHz ... 10 kHz (bidirectional HART transmission) |
Signaling
| Status display | Green LED (supply voltage) |
| LED yellow (switching state) | |
| Red LED (line errors) |
Dimensions
| Dimensional drawing | |
| Width | 17.5 mm |
| Height | 107.8 mm |
| Depth | 113.7 mm |
| Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Material specifications
| Flammability rating according to UL 94 | V0 |
| Housing material | Polyamide (PA 6.6) |
Environmental and real-life conditions
| Ambient conditions | |
| Degree of protection | IP20 (Terminal blocks) |
| IP30 (Housing) | |
| Ambient temperature (operation) | -40 °C ... 70 °C (Stand-alone device: any mounting position) |
| -40 °C ... 48 °C (Group assembly: vertical DIN rail without circulating air) | |
| -40 °C ... 58 °C (Group assembly: vertical DIN rail with circulating air) | |
| -40 °C ... 56 °C (Group assembly: horizontal DIN rail without circulating air) | |
| -40 °C ... 60 °C (Group assembly: horizontal DIN rail with circulating air) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | ≤ 95 % (non-condensing) |
Approvals
| ATEX | |
| Identification | II (1) G [Ex ia Ga] IIC |
| II (1) D [Ex ia Da] IIIC | |
| II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc | |
| I (M1) [Ex ia Ma] I | |
| IECEx | |
| Identification | [Ex ia Ga] IIC |
| [Ex ia Da] IIIC | |
| Ex nA nC [ia Ga] IIC T4 Gc | |
| [Ex ia Ma] I | |
| Safety Integrity Level (SIL, IEC 61508) | |
| Identification | 2 |
EMC data
| Electromagnetic compatibility | Tested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21 |
Standards and regulations
| Electrical isolation | 4-way isolation |
Mounting
| Mounting type | NS 35/15, NS 35/7,5 |
| Mounting position | vertical, horizontal |