PHOENIX CONTACT MACX MCR-EX-AP-2REL-2DI-LP-SP MACX MCR-EX-AP-2REL-2DI-LP-SP 1292332 PHOENIX CONTACT The relay module separates the Ex i and non-Ex i contr.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MACX MCR-EX-AP-2REL-2DI-LP-SP 1292332 PHOENIX CONTACT The relay module separates the Ex i and non-Ex i contr..

MACX MCR-EX-AP-2REL-2DI-LP-SP

1292332

PHOENIX CONTACT

1 Pcs.

The relay module separates the Ex i and non-Ex i control and signal circuits and serves for intrinsically safe control of Ex i field current circuits via one inverter relay per channel. Standard configuration, Loop-powered, 4-way separation, Safety Integrity Level (SIL, IEC 61508): 2, Push-in connection Ex i relay module separates binary Ex i and Non Ex i signal and control circuits and is used for intrinsically safe control of Ex i field circuits via one coupler relay per channel. Standard configuration, loop-powered, 4-way isolation, Safety Integrity Level (SIL, IEC 61508): 2, push-in connection

Automation > Accessories/spare parts for low-voltage switch technology
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact relay module (MACX MCR-EX-AP-2REL-2DI-LP-SP) is an interface device typically used in hazardous area applications to provide galvanic isolation between intrinsically safe Ex i field circuits and non-Ex i control systems. These modules ensure reliable signal transmission while preventing dangerous energy transfer into explosive atmospheres.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product Type: Relay Module
  • Product family: MACX Analog
  • Number of channels: 2
  • Number of channels: 2
  • Galvanic isolation: 4-way separation
  • Rated insulation voltage: 375 V SS
  • Galvanic isolation input 1 / input 2 Test voltage: 350 V (50 Hz, 60 s)
  • Supplies Supply voltage range: loop-powered, no external supply necessary
  • Power dissipation: ≤ 0.4 W
  • Taxes Description of the entrance: Control input, non-intrinsically safe
  • Input Signal Voltage: 12 V ... 31.2 V (switching signal)
  • Current consumption: < 25 mA (12 V)
  • Switching: Relay Description of the output: Intrinsically safe
  • Contact execution: 1 changeover per channel
  • Switching voltage minimum: 1 V (1 mA)
  • Switching voltage maximum: 45 V DC (0.25 A)

More info

▲

GeneralInstallation conditions affect the ambient temperature.
Please refer to the operating instructions.

Product TypeRelay Module
Product familyMACX Analog
Number of channels2

Number of channels2
Galvanic isolation4-way separation
Galvanic isolation input/output IEC/EN 60079-11
Standards/RegulationsIEC/EN 60079-11
Rated insulation voltage375 VSS
Galvanic isolation input 1 / input 2
Test voltage350 V (50 Hz, 60 s)
Supplies
Supply voltage rangeloop-powered, no external supply necessary
Power dissipation≤ 0.4 W

Taxes
Description of the entranceControl input, non-intrinsically safe
Input Signal Voltage12 V ... 31.2 V (switching signal)
Current consumption< 25 mA (12 V)
< 17 mA (24 V ... 31.2 V)

Switching: Relay
Description of the outputIntrinsically safe
Contact execution1 changeover per channel
Switching voltage minimum1 V (1 mA)
Switching voltage maximum45 V DC (0.25 A)
30 V DC (4 A)
45 V AC (4 A, cos φ >0.7)
Typical switch-on time≤ 10 ms
Typical switch-off time≤ 10 ms
Switching frequency≤ 15 Hz

Conductor cross-section AWG(converted to IEC)
Connection typePush-in connection
Stripping length8 mm
Conductor cross-section rigid0.2 mm² ... 1.5 mm²
Flexible conductor cross-section0.2 mm² ... 1.5 mm²
Conductor cross-section AWG24 ... 16

Ex installation (EPL)Gc
Ex i circuits (EPL)Ga
Since
Ma
Safety specifications
Input voltage Ui45 V AC
Input Current Ii4 A
Max. internal inductance Linegligible
Max. internal capacity Cinegligible
Safety maximum voltage Um253 V AC
Safety specifications
Input voltage Ui45 V DC
Input Current Ii0.25 A
Max. internal inductance Linegligible
Max. internal capacity Cinegligible
Safety maximum voltage Um253 V AC
Safety specifications
Input voltage Ui30 V DC
Input Current Ii4 A
Max. internal inductance Linegligible
Max. internal capacity Cinegligible
Safety maximum voltage Um253 V AC

Dimensional drawing
Width17.5 mm
Height107.8 mm
Depth113.7 mm
114.5 mm (snapped onto DIN rail NS 35/7.5 according to EN 60715)

Flammability class according to UL 94V0
Material housingPolyamide (PA 6.6)

Environmental conditions
Degree of protectionIP20 (terminals)
IP30 (enclosure)
Ambient temperature (operating)-20 °C ... 70 °C (single unit: installation position any)
-20 °C ... 70 °C (group mounting: vertical mounting rail without recirculating air)
-20 °C ... 70 °C (group mounting: vertical mounting rail with recirculating air)
-20 °C ... 70 °C (group mounting: horizontal mounting rail without recirculating air)
-20 °C ... 70 °C (group mounting: horizontal mounting rail with recirculating air)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible humidity (operating)≤ 95% (no condensation)

ATEX
Marking II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3(1) G Ex ec nC [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
IECEx
Marking[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec nC [ia Ga] IIC T4 Gc
[Ex ia Ma] I
Safety Integrity Level (SIL, IEC 61508)
Marking2

Electromagnetic compatibilityTested according to the following standards and regulations: EN 61326-1 Industrial Use, NAMUR NE 21

Galvanic isolation4-way separation

Mounting typeNS 35/15, NS 35/7,5
Installation positionvertical, horizontal

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.