View larger
CTM ISDN 2838555 PHOENIX CONTACT Surge protection plug
CTM ISDN
2838555
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact CTM ISDN 2838555 PHOENIX CONTACT Surge protection plug is a specialized component engineered to safeguard sensitive telecommunication infrastructure from sudden voltage spikes and transient overvoltages. In industrial control and signal distribution panels, surge protection devices are routinely installed to protect low-voltage communication loops and data lines against the damaging effects of switching operations and atmospheric discharges.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Nominal voltage AC (EF008798): 6 V
More info
▲Key Commercial Data
| Orderkey | 2838555 |
|---|---|
| Packing unit | 10 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 167 (C-4-2017) |
| GTIN | 4017918819583 |
| Weight per Piece (excluding packing) | 9.090 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
General
| Housing material | PA |
|---|---|
| Flammability rating according to UL 94 | V-0 |
| Color | black |
| Standards for cearances and creepage distances | DIN VDE 0110-1 |
| IEC 60664-1 | |
| Overvoltage category | II |
| Degree of pollution | 2 |
| Mounting type | On CT-TERMIBLOCK and LSA-PLUS disconnect strip |
| Type | LSA-PLUS module |
| Number of positions | 2 |
| Direction of action | Line-Line & Line-Earth Ground |
| Arrester can be tested with CHECKMASTER from software version: | From SW rev. 1.10 |
Protective circuit
| IEC test classification | B2 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| C1 | |
| VDE requirement class | B2 |
| C2 | |
| C3 | |
| D1 | |
| C1 | |
| Nominal voltage UN | 6 V DC |
| Maximum continuous voltage UC | ± 6 V DC |
| Rated current | 1.5 A (25 °C) |
| Residual current IPE | ≤ 2 µA |
| Nominal discharge current In(8/20) µs (line-line) | 350 A |
| Nominal discharge current In(8/20) µs (line-earth) | 5 kA |
| Pulse discharge current Iimp(10/350) µs (line-earth) | 1 kA |
| Total discharge current Itotal(8/20) µs | 10 kA |
| Total discharge current Itotal(10/350) µs | 2.5 kA |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 10 kA (in total) |
| Nominal pulse current Ian (10/1000) µs (line-line) | 100 A |
| 100 A | |
| Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 60 V |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 700 V |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 15 V |
| Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 700 V |
| Residual voltage at In(line-line) | ≤ 32 V |
| Residual voltage at In(line-earth) | ≤ 55 V |
| Residual voltage with Ian (10/1000) µs (line-line) | ≤ 18 V |
| Residual voltage with Ian (10/1000) µs (line-earth) | ≤ 12 V |
| Voltage protection level Up(line-line) | ≤ 35 V (C1 - 700 V/350 A) |
| ≤ 18 V (C3, 7.5 kV/100 A) | |
| Voltage protection level Up(line-earth) | ≤ 700 V (C2 - 10 kV/5 kA, spike) |
| ≤ 55 V (C2 - 10 kV/5 kA, static) | |
| ≤ 700 V (C3 - 7.5 kV / 100 A, spike) | |
| ≤ 12 V (C3 - 7.5 kV / 100 A, static) | |
| Response time tA(line-line) | ≤ 500 ns |
| Response time tA(line-earth) | ≤ 100 ns |
| Input attenuation aE, sym. | 0.3 dB (≤ 45 MHz) |
| Cut-off frequency fg (3 dB), sym. in 100 Ohm system | ≥ 100 MHz |
| Capacity (line-line) | 25 pF (f=1 MHz / VR= 0 V) |
| Surge protection fault message | none |
| Impulse durability (line-line) | C2 - 4 kV / 2 kA |
| C3 - 100 A | |
| B2 - 4 kV/100 A | |
| Impulse durability (line-earth) | C2 - 4 kV/2 kA |
| C3 - 100 A | |
| B2 - 4 kV/100 A | |
| D1 - 1 kA |
Connection data
| Connection method | can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips |
|---|---|
| Connection method IN | COMTRAB plug-in system |
| Connection method OUT | COMTRAB plug-in system |
| Connection technology | LSA-PLUS |