View larger
LPWAN SCU DOR2 230V EU 1427695 PHOENIX CONTACT SCU (Segment Control Unit) for lighting control based on astr..
LPWAN SCU DOR2 230V EU
1427695
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - communication module
Control Systems (CST)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered to manage outdoor illumination arrays automatically, this LPWAN SCU DOR2 230V EU 1427695 PHOENIX CONTACT SCU (Segment Control Unit) for lighting control based on astr.. coordinates scheduling and switching tasks based on astronomical timing data. These controllers optimize energy consumption in municipal and industrial lighting applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Radio Module
- Insulation characteristics Security class: II (plastic enclosures)
- Feeding Supply voltage range: 100 V AC ... 240 V AC ±10 %
- Input: 0.3 W
- Digital Output Name: Relay output
- Number of outputs: 2
- Contact Switching Type: Closing contact
- Contact material: AgNi
- Max. switchable voltage: 230 V +10 %
- Max. inrush current: 10 A (at 230 V AC -20 % ...+15 %)
- Conductor cross-section AWG: (converted according to IEC)
- Link: Screw connection with cage
- Stripping length: 10 mm
- Rigid conductor cross-section min.: 0.2 mm²
- Solid conductor cross-section max.: 6 mm²
- Flexible conductor cross-section min.: 0.2 mm²
More info
▲| Product Type | Radio Module |
| Insulation characteristics | |
| Security class | II (plastic enclosures) |
| Feeding | |
| Supply voltage range | 100 V AC ... 240 V AC ±10 % |
| Input | 0.3 W |
| Digital | |
| Output Name | Relay output |
| Number of outputs | 2 |
| Contact Switching Type | Closing contact |
| Contact material | AgNi |
| Max. switchable voltage | 230 V +10 % |
| Max. inrush current | 10 A (at 230 V AC -20 % ...+15 %) |
| Conductor cross-section AWG | (converted according to IEC) |
| Link | Screw connection with cage |
| Stripping length | 10 mm |
| Rigid conductor cross-section min. | 0.2 mm² |
| Solid conductor cross-section max. | 6 mm² |
| Flexible conductor cross-section min. | 0.2 mm² |
| Flexible conductor cross-section max. | 6 mm² |
| Conductor cross-section AWG min. | 24 |
| Conductor cross-section AWG max. | 10 |
| Radio transmitters | |
| Maximum transmission capacity | < 14 dBm |
| Functions | |
| Basic functionality | Control of street lighting via relays |
| Automatic channel selection | ADR |
| Radio certifications | bb |
| Country support | Egypt |
| Albania | |
| Andorra | |
| Armenia | |
| Austria | |
| Bahrain | |
| Bangladesh | |
| Belarus | |
| Belgium | |
| Burma (Myanmar) | |
| Bosnia/Herzegovina | |
| Brunei Darussalam | |
| Bulgaria | |
| Cambodia | |
| Croatia | |
| Cyprus | |
| Czech Republic | |
| Denmark | |
| Estonia | |
| Finland | |
| France | |
| Germany | |
| Greece | |
| Iceland | |
| Hungary | |
| Iran | |
| Italy | |
| Laos | |
| Latvia | |
| Lebanon | |
| Liechtenstein | |
| Lithuania | |
| Luxembourg | |
| Macedonia | |
| Malta | |
| Moldova | |
| Montenegro | |
| Morocco | |
| Netherlands | |
| New Zealand | |
| Nigeria | |
| Norway | |
| Oman | |
| Pakistan | |
| Philippines | |
| Poland | |
| Katar | |
| Romania | |
| Saudi Arabia | |
| Serbia | |
| Singapore | |
| Slovakia | |
| Slovenia | |
| South Africa | |
| Spain | |
| Sweden | |
| Switzerland | |
| Tunisia | |
| Turkey | |
| Ukraine | |
| United Arab Emirates | |
| Great Britain | |
| Ireland | |
| Portugal | |
| Vietnam | |
| Wireless | |
| Denomination | LoRaWANEU 868 |
| Antenna connection type | SMA (female) |
| Number | 1 |
| Frequency | 868.1 MHz ... 869.525 MHz |
| Frequency band | 868 MHz |
| Radio standards | LoRaWAN |
| Transmission sensitivity | < 14 dBm |
| Coverage | up to 15 Km |
| Transmission physics | LoRa |
| Number of radio interfaces | 1 |
| Dimensioned Drawing | |
| width | 79.3 mm |
| height | 207.3 mm |
| Depth | 37.4 mm |
| Environmental conditions | |
| Degree of protection | IP43 |
| Ambient temperature (operating) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Permissible humidity (operation) | 0 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 0 % ... 95 % |
| Ec | |
| Marking | CE Compliance |
| Compliance with EMC directives | Verification of interference immunity according to EN 301489-1 Electrostatic discharge (ESD) Criterion A, 4 kV contact discharge, 8 kV air discharge |
| Electromagnetic fields Criterion A, field strength: 10 V/m | |
| Fast Transients (Burst) Criterion A, 2 kV | |
| Transient overvoltage (Surge) Criterion A , ±1 kV (symmetrical) | |
| Extent of interference in the network Criterion A, test voltage 10 V | |
| Noise emission verification according to EN IEC 55015 | |
| Electromagnetic Compatibility | Compliance with EMC Directive 2014/30/EU |
| Mounting type | DIN rail mounting or wall mounting |