LPS-8/E 3270560 PHOENIX CONTACT Service connector, rated voltage: 800 V, rated current: 24 A, number of pole..
LPS-8/E
3270560
PHOENIX CONTACT
25 Pcs.
Automation > Test plug for terminal blocks
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A LPS-8/E 3270560 PHOENIX CONTACT Service connector, rated voltage: 800 V, rated current: 24 A, number of pole.. provides temporary or permanent bridging capabilities in industrial control architectures, ensuring consistent current distribution across modular blocks. These connectors maintain secure contact under demanding electrical loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Test plug terminal block
- Number of positions: 1
- Stripping length: 8 mm ... 10 mm
- Connection in acc. with standard: IEC 60947-7-1
- Conductor cross section rigid: 0.14 mm² ... 4 mm²
- Cross section AWG: 26 ... 12 (converted acc. to IEC)
- Conductor cross section flexible: 0.14 mm² ... 4 mm²
- Conductor cross section, flexible [AWG]: 26 ... 12 (converted acc. to IEC)
- Nominal current: 24 A
- Nominal voltage: 800 V
- Nominal cross section: 2.5 mm²
- Conductor cross section, rigid [AWG]: 20 ... 12 (converted acc. to IEC)
- Conductor cross section flexible: 0.5 mm² ... 2.5 mm²
- Conductor cross section, flexible [AWG]: 14 (converted acc. to IEC)
- Width: 8.2 mm
- Height: 18.5 mm
More info
▲| Product type | Test plug terminal block |
| Number of positions | 1 |
| Stripping length | 8 mm ... 10 mm |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section rigid | 0.14 mm² ... 4 mm² |
| Cross section AWG | 26 ... 12 (converted acc. to IEC) |
| Conductor cross section flexible | 0.14 mm² ... 4 mm² |
| Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Nominal current | 24 A |
| Nominal voltage | 800 V |
| Nominal cross section | 2.5 mm² |
| Connection cross sections directly pluggable | |
| Conductor cross section rigid | 0.5 mm² ... 4 mm² |
| Conductor cross section, rigid [AWG] | 20 ... 12 (converted acc. to IEC) |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 14 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Width | 8.2 mm |
| Height | 18.5 mm |
| Depth | 60.4 mm |
| Color | red |
| Material | PA |
| Flammability rating according to UL 94 | V0 |
| Static insulating material application in cold | -60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 125 °C |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C (max. operating temperature see derating curve) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection in acc. with standard | IEC 60947-7-1 |