LPCH 6/ 5+4-STL5-7,62 1717003 PHOENIX CONTACT PCB hybrid connector assemblies integrate mixed power and signal paths into a single interface for advanced industrial devices. Design engineers utilize these hybrid terminals to optimize layout space within dense electronics enclosures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of plug-in contact rows (EF006935): 1
- Modular spacing contacts (EF007326): 7.62 mm
- Modular spacing connections (EF006827): 7.62 mm
- Rated current In (EF008250): 41 A
- Rated voltage (EF000228): 1000 V
- Connectable conductor cross section solid-core (EF007337): 0.75 mm²
- Connectable conductor cross section multi-wired (EF007343): 10 mm²
- Material of contact surface (EF004020): Tin
- Material contact (EF007544): Copper
- Housing colour (EF000136): Green
- Operating temperature (EF002393): -40 °C
More info
▲Key Commercial Data
| Orderkey | 1717003 |
|---|---|
| Packing unit | 1 pc |
| Minimum order quantity | 25 pc |
| GTIN | 4055626532585 |
| Weight per Piece (excluding packing) | 44.000 g |
| Custom tariff number | 85366990 |
| Country of origin | PL (Poland) |
Item properties
| Brief article description | PCB hybrid connector |
|---|---|
| Plug-in system | POWER COMBICON 6 Hybrid |
| Type of contact | Female connector |
| Range of articles | LPCH 6/..-STL |
| Pitch | 7.62 mm |
| 3.81 mm | |
| Number of positions | 9 |
| Connection method | Push-in spring connection |
| Locking | Latch mechanism/latching at position 5 |
| Number of levels | 1 |
| 2 | |
| Number of connections | 9 |
| Number of potentials | 9 |
Power connection capacity
| Conductor cross section solid | 0.75 mm² ... 10 mm² |
|---|---|
| Conductor cross section flexible | 0.75 mm² ... 6 mm² |
| Conductor cross section AWG / kcmil | 18 ... 8 |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.75 mm² ... 6 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.75 mm² ... 6 mm² |
| Cylindrical gauge a x b / diameter | 4.3 mm x 4.0 mm / 4.0 mm |
| Stripping length | 18 mm |
Connection capacity signal
| Conductor cross section solid | 0.2 mm² ... 1.5 mm² |
|---|---|
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG / kcmil | 24 ... 16 |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1 mm² |
| Cylindrical gauge a x b / diameter | 2.4 mm x 1.5 mm / 1.5 mm |
| Stripping length | 10 mm |
Material data - contact
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
|---|---|
| Contact material | Cu alloy |
| Surface characteristics | Tin-plated |
| Metal surface terminal point (top layer) | Tin (4 - 8 µm Sn) |
| Metal surface contact area (top layer) | Tin (4 - 8 µm Sn) |
Material data - housing
| Insulating material | PA GF |
|---|---|
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | V0 |
Material data – actuating element
| Insulating material | PA GF |
|---|---|
| CTI according to IEC 60112 | 600 |
| Flammability rating according to UL 94 | V0 |
Dimensions for the product
| Length [ l ] | 48 mm |
|---|---|
| Width [ w ] | 55.54 mm |
| Height [ h ] | 35.65 mm |
| Pitch | 7.62 mm |
| Dimension a | 38.1 mm |
Packaging information
| Type of packaging | packed in cardboard |
|---|---|
| Pieces per package | 25 |
| Denomination packing units | Pcs. |
Ambient conditions
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 100 °C (dependent on the derating curve) |
Termination and connection method
| Conductor connection test | The stripped-off ends of the largest conductor can be completely inserted in the opening of the terminal point without using excessive force. |
|---|---|
| Test result | Test passed |
| Test – repeated connection and release | IEC 60999-1:1999-11 |
| Test passed | |
| Test for conductor damage and slackening | IEC 60999-1:1999-11 |
| Test passed |
Pull-out test
| Pull-out test | IEC 60999-1:1999-11 |
|---|---|
| Test passed | |
| Conductor cross section / conductor type / tensile force | 0.75 mm² / solid / > 30 N |
| 0.75 mm² / flexible / > 30 N | |
| 10 mm² / solid / > 90 N | |
| 6 mm² / flexible / > 80 N |
Mechanical tests according to standard
| Visual examination | Test passed IEC 60512-1-1:2002-02 |
|---|---|
| Dimensional test | Test passed IEC 60512-1-2:2002-02 |
| Resistance of marking | Test passed IEC 60068-2-70:1995-12 |
| Result | Test passed |
| Specification | IEC 60512-13-2:2006-02 |
| No. of cycles | 25 |
| Insertion strength per pos. approx. | 7 N |
| Withdraw strength per pos. approx. | 4 N |
| Polarization and coding | Test passed IEC 60512-13-5:2006-02 |
| Result | Test passed |
| Specification | IEC 60512-15-1:2008-05 |
| Test force per pos. | 20 N |
Air clearances and creepage distances
| Clearances and creepage distances | IEC 60664-1:2007-04 |
|---|---|
| Specification | IEC 60664-1:2007-04 |
| Rated insulation voltage (III/3) | 800 V |
| Rated insulation voltage (III/2) | 1000 V |
| Rated insulation voltage (II/2) | 1000 V |
| Rated surge voltage (III/3) | 8 kV |
| Rated surge voltage (III/2) | 8 kV |
| Rated surge voltage (II/2) | 6 kV |
| Minimum clearance - inhomogeneous field (III/3) | 8 mm |
| Minimum clearance - inhomogeneous field (III/2) | 8 mm |
| Minimum clearance - inhomogeneous field (II/2) | 5.5 mm |
| Minimum creepage distance value (III/3) | 10 mm |
| Minimum creepage distance value (III/2) | 5 mm |
| Minimum creepage distance value (II/2) | 5 mm |
Temperature cycles
| Specification | IEC 60999-1:1999-11 |
|---|---|
| Test current (minimum cross section) | 9 A DC |
| Test current (maximum cross section) | 41 A DC |
| Temperature cycles | 192 |
Mechanical tests (A)
| Insertion strength per pos. approx. | 7 N |
|---|---|
| Withdraw strength per pos. approx. | 4 N |
| Polarization when inserted requirement >20 N | Test passed |
| Contact holder in insert requirements >20 N | Test passed |
Durability tests (B)
| Specification | IEC 60512-9-1:2010-03 |
|---|---|
| Contact resistance R1 | 0.42 mΩ |
| Insertion/withdrawal cycles | 25 |
| Contact resistance R2 | 0.46 mΩ |
| Impulse withstand voltage at sea level | 7.3 kV |
| Power-frequency withstand voltage | 3.31 kV |
| Insulation resistance, neighboring positions |
Climatic tests (D)
| Specification | ISO 6988:1985-02 |
|---|---|
| Cold stress | -40 °C/2 h |
| Thermal stress | 100 °C/168 h |
| Corrosive stress | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Impulse withstand voltage at sea level | 7.3 kV |
| Power-frequency withstand voltage | 3.31 kV |
Environmental and durability tests (E)
| Specification | IEC 61984:2008-10 |
|---|---|
| Result, degree of protection, IP code | Back of hand safety with IP10 access probe |
Classifications
eCl@ss
| eCl@ss 4.0 | 27260700 |
|---|---|
| eCl@ss 4.1 | 27260700 |
| eCl@ss 5.0 | 27260700 |
| eCl@ss 5.1 | 27260700 |
| eCl@ss 6.0 | 27260700 |
| eCl@ss 7.0 | 27440309 |
| eCl@ss 8.0 | 27440309 |
| eCl@ss 9.0 | 27440309 |