A Phoenix Contact LPCH 6/ 5+4-ST-7,62 connector, hybrid printed circuit board combines signal and power transmission capabilities into a single unified pluggable interface. Hybrid connectors optimize space utilization on circuit boards within demanding power electronics and control systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: PCB Hybrid Connectors
- Product family: LPCH 6/.. +4-H Product Line: COMBICON Connectors L
- Number of poles: 9
- Grid dimension: 7.62 mm
- Number of ports: 9
- Number of rows: 1
- Number of potentials: 9
- Data maintenance status Article revision: 05
- Nominal current I N: 41 A
- Rated voltage U N: 1000 V
- Contact resistance: 0.42 mΩ
- Rated voltage (III/3): 800 V
- Rated Surge Voltage (III/3): 8 kV
- Rated voltage (III/2): 1000 V
- Rated Surge Voltage (III/2): 8 kV
More info
▲| Product Type | PCB Hybrid Connectors |
| Product family | LPCH 6/.. +4-H |
| Product Line | COMBICON Connectors L |
| Number of poles | 9 |
| Grid dimension | 7.62 mm |
| Number of ports | 9 |
| Number of rows | 1 |
| Number of potentials | 9 |
| Data maintenance status | |
| Article revision | 05 |
| Nominal current IN | 41 A |
| Rated voltage UN | 1000 V |
| Contact resistance | 0.42 mΩ |
| Rated voltage (III/3) | 800 V |
| Rated Surge Voltage (III/3) | 8 kV |
| Rated voltage (III/2) | 1000 V |
| Rated Surge Voltage (III/2) | 8 kV |
| Rated voltage (II/2) | 1000 V |
| Rated Surge Voltage (II/2) | 6 kV |
| Connection technology | |
| Connector system | COMBICON PC 6 hybrid |
| Nominal cross-section | 6 mm² |
| Contact type | Socket |
| Locking | |
| Lock type | without |
| Mounting Flange | without |
| Conductor Connection Power | |
| Connection type | Lever push-in connection |
| Connection direction of the conductor to the mating direction | 0 ° |
| Conductor cross-section rigid | 0.75 mm² ... 10 mm² |
| Flexible conductor cross-section | 0.75 mm² ... 6 mm² |
| Conductor cross-section AWG | 18 ... 8 |
| Flexible conductor cross-section with ferrule without plastic sleeve | 0.75 mm² ... 6 mm² |
| Flexible conductor cross-section with ferrule with plastic sleeve | 0.75 mm² ... 6 mm² |
| Gauge mandrel a x b / diameter | 4.3 mm x 4.0 mm / 4.0 mm |
| Stripping length | 18 mm |
| Conductor connection signal | |
| Connection type | Push-in spring connection |
| Connection direction of the conductor to the mating direction | 0 ° |
| Conductor cross-section rigid | 0.2 mm² ... 1.5 mm² |
| Flexible conductor cross-section | 0.2 mm² ... 1.5 mm² |
| Conductor cross-section AWG | 24 ... 16 |
| Flexible conductor cross-section with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Flexible conductor cross-section with ferrule with plastic sleeve | 0.25 mm² ... 1 mm² |
| Gauge mandrel a x b / diameter | 2.4 mm x 1.5 mm / 1.5 mm |
| Stripping length | 10 mm |
| Material information - Contact | |
| Note | WEEE/RoHS compliant, whisker-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Material Contact | Cu alloy |
| Surface finish | Electroplated |
| Metal surface clamping point (top layer) | Tin (4 - 8 μm Sn) |
| Metal Surface Contact Area (Top Layer) | Tin (4 - 8 μm Sn) |
| Material specifications - Housing | |
| Color (Housing) | Green (6021) |
| Insulating material | PA GF |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flammability class according to UL 94 | V0 |
| Material specifications - Actuator | |
| Color (Actuator) | orange (2003) |
| Insulating material | PA GF |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flammability class according to UL 94 | V0 |
| Note on operation | COMBICON connectors are connectors without switching capacity (COC) in accordance with DIN EN 61984. When used as intended, they must not be plugged in or disconnected in a live or under load. |
| Dimensional drawing | |
| Grid dimension | 7.62 mm |
| Width [w] | 47.92 mm |
| Height [h] | 35.65 mm |
| Length [l] | 48 mm |
| Conductor connection | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Exam passed |
| Inspection for conductor damage and loosening | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Exam passed |
| Inspection for conductor damage and loosening | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Exam passed |
| Connecting and disconnecting multiple times | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Exam passed |
| Tensile testing | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Conductor cross-section/Conductor type/Tensile force Setpoint/Actual value | 0.75 mm² / rigid / > 30 N |
| 0.75 mm² / flexible / > 30 N | |
| 10 mm² / rigid / > 90 N | |
| 6 mm² / flexible / > 80 N | |
| Tensile testing | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Conductor cross-section/Conductor type/Tensile force Setpoint/Actual value | 0.2 mm² / rigid / > 10 N |
| 0.2 mm² / flexible / > 10 N | |
| 1.5 mm² / rigid / > 40 N | |
| 1.5 mm² / flexible / > 40 N | |
| Mating and pulling forces | |
| Result | Exam passed |
| Number of cycles | 25 |
| Insertion force per pole approx. | 7 N |
| Pulling force per pole approx. | 4 N |
| Contact holder in use | |
| Test Specification | DIN EN 60512-15-1:2009-03 |
| Contact holder in use Requirement >20 N | Exam passed |
| Durability of inscriptions | |
| Test Specification | DIN EN 60068-2-70:1996-07 |
| Result | Exam passed |
| Polarization and Coding | |
| Test Specification | DIN EN 60512-13-5:2006-11 |
| Result | Exam passed |
| Visual inspection | |
| Test Specification | DIN EN 60512-1-1:2003-01 |
| Result | Exam passed |
| Dimensional inspection | |
| Test Specification | DIN EN 60512-1-2:2003-01 |
| Result | Exam passed |
| Thermal Testing Test Group C | |
| Test Specification | DIN EN 60512-5-1:2003-01 |
| Tested number of poles | 4 |
| Insulation resistance | |
| Test Specification | DIN EN 60512-3-1:2003-01 |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Temperature cycles | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Exam passed |
| Clearance and creepage distances Power | |
| Test Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulating material group | I |
| Tracking resistance (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Rated insulation voltage (III/3) | 800 V |
| Rated Surge Voltage (III/3) | 8 kV |
| Minimum air distance value - inhomogeneous field (III/3) | 8 mm |
| Minimum value of the creepage distance (III/3) | 10 mm |
| Rated insulation voltage (III/2) | 1000 V |
| Rated Surge Voltage (III/2) | 8 kV |
| Minimum value of the air distance - inhomogeneous field (III/2) | 8 mm |
| Minimum value of the creepage distance (III/2) | 8 mm |
| Rated insulation voltage (II/2) | 1000 V |
| Rated Surge Voltage (II/2) | 6 kV |
| Minimum value of the clearance - inhomogeneous field (II/2) | 5.5 mm |
| Minimum value of the creepage distance (II/2) | 5.5 mm |
| Clearance and creepage distances Signal | |
| Test Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulating material group | I |
| Tracking resistance (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Rated insulation voltage (III/3) | 160 V |
| Rated Surge Voltage (III/3) | 2.5 kV |
| Minimum air distance value - inhomogeneous field (III/3) | 1.5 mm |
| Minimum value of the creepage distance (III/3) | 2 mm |
| Rated insulation voltage (III/2) | 160 V |
| Rated Surge Voltage (III/2) | 2.5 kV |
| Minimum value of the air distance - inhomogeneous field (III/2) | 1.5 mm |
| Minimum value of the creepage distance (III/2) | 1.5 mm |
| Rated insulation voltage (II/2) | 320 V |
| Rated Surge Voltage (II/2) | 2.5 kV |
| Minimum value of the clearance - inhomogeneous field (II/2) | 1.5 mm |
| Minimum value of the creepage distance (II/2) | 1.6 mm |
| Vibration testing | |
| Test Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| Frequency | 10 - 150 - 10 Hz |
| Sweep Speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Test duration per axis | 2.5 h |
| Test Directions | X, Y and Z axis |
| Durability test | |
| Test Specification | DIN EN 60512-9-1 (VDE 0687-512-9-1):2010-12 |
| Standing Shock Stress at Sea Level | 7.3 kV |
| Contact resistance R1 | 0.42 mΩ |
| Contact resistance R2 | 0.46 mΩ |
| Mating cycles | 25 |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Climatic testing | |
| Test Specification | DIN EN ISO 6988:1997-03 |
| Corrosion stress | 0.2 dm3SO2to 300 DM3/40 °C/1 cycle |
| Heat stress | 100 °C/168 h |
| Standing AC voltage | 3.31 kV |
| Environmental conditions | |
| Ambient temperature (operating) | -40 °C ... 105 °C (depending on the derating curve) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Relative humidity (storage/transport) | 30 % ... 70 % |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Packaging type | packed in carton |