PHOENIX CONTACT LP 2,5/ 5 LP 2,5/ 5 1071716 PHOENIX CONTACT Connector, rated voltage: 800 V, rated current: 24 A, number of poles: 5, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

LP 2,5/ 5 1071716 PHOENIX CONTACT Connector, rated voltage: 800 V, rated current: 24 A, number of poles: 5, ..

LP 2,5/ 5

1071716

PHOENIX CONTACT

50 Pcs.

Connector, rated voltage: 800 V, rated current: 24 A, number of poles: 5, connection type: Push-in connection, Sizing cross-section: 2.5 mm², cross-section: 0.14 mm²- 4 mm², color: gray Connector, nominal voltage: 800 V, nominal current: 24 A, number of poles: 5, connection type: Push-in connection, Dimensioning section: 2.5 mm², cross-section: 0.14 mm²- 4 mm², color: grey Plug, nom. voltage: 800 V, nominal current: 24 A, number of positions: 5, connection method: Push-in connection, Rated cross section: 2.5 mm2, cross section: 0.14 mm2- 4 mm2, color: gray

Connectors > Terminal block connector
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact LP 2,5/ 5 connector (1071716) provides dependable wire-to-board or modular electrical interfacing for power distribution networks. These connection components ensure secure mechanical retention and low-resistance electrical contact across multi-pole industrial setups. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Terminal plug
  • Number of positions: 5
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Rated surge voltage: 8 kV
  • Nominal cross section: 2.5 mm²
  • Stripping length: 8 mm ... 10 mm
  • Connection in acc. with standard: IEC 60947-7-1
  • Conductor cross section rigid: 0.14 mm² ... 4 mm²
  • Cross section AWG: 26 ... 12 (converted acc. to IEC)
  • Conductor cross section flexible: 0.14 mm² ... 4 mm²
  • Conductor cross section, flexible [AWG]: 26 ... 12 (converted acc. to IEC)
  • Nominal current: 24 A
  • Maximum load current: 24 A (with 4 mm² conductor cross-section)
  • Nominal voltage: 800 V
  • Nominal cross section: 2.5 mm²

More info

▲
Technical data

Product properties
Product typeTerminal plug
Number of positions5
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage8 kV

Connection data
Nominal cross section2.5 mm²
Stripping length8 mm ... 10 mm
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.14 mm² ... 4 mm²
Cross section AWG26 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Nominal current24 A
Maximum load current24 A (with 4 mm² conductor cross-section)
Nominal voltage800 V
Nominal cross section2.5 mm²
Connection cross sections directly pluggable
Conductor cross section rigid0.5 mm² ... 4 mm²
Conductor cross section, rigid [AWG]20 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.5 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mm² ... 2.5 mm²

Dimensions
Width25.8 mm
Height18.6 mm
Depth40.3 mm
Length18.6 mm

Material specifications
Colorgray
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-1