View larger
IPCH-4X-PCL-TCP-24DC-UT 1045379 PHOENIX CONTACT Evaluation unit for the real-time recording of surge current..
IPCH-4X-PCL-TCP-24DC-UT
1045379
PHOENIX CONTACT
1 Pcs.
Automation > Measurement device for surge protection
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Evaluation units for real-time surge current recording process sensor data to give facility teams immediate visibility into lightning strikes and transient energy events. The Phoenix Contact part number IPCH-4X-PCL-TCP-24DC-UT mounts onto standard DIN rails to monitor electrical infrastructure. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1045379
- Packing unit: 1
- Catalog page: Page 213 (C-4-2019)
- GTIN: 4055626633879
- Custom tariff number: 85437090
- Horizontal pitch: 1.3 Div.
- Ambient temperature (operation): -25 °C ... 60 °C
- Ambient temperature (storage/transport): -35 °C ... 85 °C
- Permissible humidity (operation): 30 % ... 95 % (non-condensing)
- Permissible humidity (storage/transport): 30 % ... 95 % (non-condensing)
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Housing material: Polyamide
- Color: traffic grey A RAL 7042
- Mounting type: DIN rail: 35 mm
- Type: DIN rail module, one-piece
- Supports cloud computing: yes
More info
▲Key Commercial Data
| Orderkey | 1045379 |
|---|---|
| Packing unit | 1 |
| Catalog page | Page 213 (C-4-2019) |
| GTIN | 4055626633879 |
| Custom tariff number | 85437090 |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -35 °C ... 85 °C |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 30 % ... 95 % (non-condensing) |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
General
| Housing material | Polyamide |
|---|---|
| Color | traffic grey A RAL 7042 |
| Mounting type | DIN rail: 35 mm |
| Type | DIN rail module, one-piece |
| Supports cloud computing | yes |
| Cloud platform | Proficloud |
Typical characteristics
| Interface | Ethernet |
|---|---|
| Number | 1 |
| Connection method | RJ45 |
| Note on the connection method | pluggable |
| Transmission speed | 10/100 Mbps |
| Basic functions | Acquisition of sensor data |
| Operation | via Proficloud application and web interface |
| Operating voltage | 24 V DC (-15% ... +20% including all tolerances and ripple) |
| Operating current | ≤ 70 mA |
| Detectable values (current strength) | 100 A ... 40 kA |
| Sampling rate | 500 kHz |
| Maximum measuring period | 1 s |
Connections
| Connection name | 24 V supply |
|---|---|
| Connection method | Screw terminal block |
| Number of connections | 4 |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Stripping length | 8 mm |
| Note | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
Remote indication contact
| Connection name | SPD remote indication contact monitoring |
|---|---|
| Connection method | Screw terminal block |
| Screw thread | M3 |
| Stripping length | 8 mm |
EMC Directives
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | Noise immunity test in accordance with EN 61000-6-2 Noise emission EN 61000-6-3/IEC 61000-6-3 Class B |
| Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1 kV |
| Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2.2 kV |
| Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
| Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
| Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |