View larger
VIP-2/SC/FLK14/8M/PLC 2322281 PHOENIX CONTACT Passive module
VIP-2/SC/FLK14/8M/PLC
2322281
PHOENIX CONTACT
1 Pcs.
Automation > Interface module
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A VIP-2/SC/FLK14/8M/PLC 2322281 PHOENIX CONTACT passive module routes control signals seamlessly between pre-assembled system cables and conventional screw-type terminal blocks. Passive interface blocks are frequently utilized in industrial automation environments to bridge programmable controllers with plant floor machinery without active electronic transformation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electrical connection, field-sided (EF005525): Screw connection
- Type of electrical connection, control sided (EF008549): Blade terminal
- Number of poles (EF001391): 14
- Rated voltage (EF000228): 25 V
- Rated current (EF000227): 1 A
- Depth (EF000049): 56 mm
- Width (EF000008): 50 mm
- Height (EF000040): 65.5 mm
- Mounting method (EF000003): DIN rail (top hat rail) 35 mm
More info
▲Key Commercial Data
| Orderkey | 2322281 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 528 (C-5-2017) |
| GTIN | 4046356451178 |
| Weight per Piece (excluding packing) | 116.000 g |
| Custom tariff number | 85366990 |
| Country of origin | US (United States) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 50 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
General
| Max. perm. operating voltage | 60 V DC |
|---|---|
| Max. perm. current (per branch) | 1 A |
| Max. permissible current (separate power supply) | 3 A (per byte) |
| Number of positions | 14 |
| Status display | No |
| Mounting position | any |
Connection data for connection 1
| Connection name | Field level |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Number of positions | 14 |
Connection data for connection 2
| Connection name | Controller level |
|---|---|
| Connection method | IDC/FLK pin strip |
| Number of connections | 1 |
| Number of positions | 14 |
| Pitch | 2.54 mm |
Supported controller
| Controller | SIEMENS S7-1500 |
|---|---|
| - suitable I/O card | 6ES7 521-1BH00-0AB0 |
| 6ES7 521-1BH50-0AA0 | |
| 6ES7 521-1BL00-0AB0 | |
| 6ES7 522-1BH00-0AB0 | |
| 6ES7 522-1BH01-0AB0 | |
| 6ES7 522-1BL00-0AB0 | |
| 6ES7 522-1BL01-0AB0 | |
| Controller | ABB S800 I/O |
| - suitable I/O card | DI814 |
| DO810 | |
| DO840 | |
| Controller | ALLEN-BRADLEY ControlLogix |
| - suitable I/O card | 1756-IB32 |
| 1756-OB32 | |
| 1756-IN16 | |
| 1756-IB16 | |
| 1756-IC16 | |
| 1756-OB16E | |
| Controller | ALLEN-BRADLEY PLC 5 |
| - suitable I/O card | 1771 IBN |
| 1771 OBN | |
| Controller | ALLEN-BRADLEY SLC 500 |
| - suitable I/O card | 1746 OB16 |
| 1746 OV16 | |
| 1746 OG16 | |
| 1746 IA16 | |
| 1746 ITB16 | |
| 1746 IN16 | |
| 1746 IV16 | |
| 1746 ITV16 | |
| 1746 IG16 | |
| 1746 OB 32 | |
| 1746 OV 32 | |
| 1746 IB 32 | |
| 1746 IV 32 | |
| 1746 IB16 | |
| Controller | GE-FANUC 90-30 |
| - suitable I/O card | IC693 MDL241 |
| IC693 MDL634 | |
| IC693 MDL645 | |
| IC693 MDL646 | |
| IC693 MDL732 | |
| IC693 MDL733 | |
| IC693 MDL740 | |
| IC693 MDL741 | |
| IC693 MDL742 | |
| Controller | GE-FANUC RX3i |
| - suitable I/O card | IC694MDL754 |
| IC694MDL660 | |
| Controller | HONEYWELL Experion PKS C200 |
| - suitable I/O card | TC-IDD 321 |
| TC-ODD 321 | |
| Controller | MITSUBISHI MELSEC L |
| - suitable I/O card | LX41C4 |
| LX42C4 | |
| LY41NT1P | |
| LY42NT1P | |
| LY41PT1P | |
| LY42PT1P | |
| Controller | MITSUBISHI MELSEC Q |
| - suitable I/O card | QX81 |
| QY81P | |
| QX41 | |
| QX41-S1 | |
| QX42 | |
| QX42-S1 | |
| QX71 | |
| QX72 | |
| QY41P | |
| QY42P | |
| QY71 | |
| QH42P | |
| QX82 | |
| QX82-S1 | |
| QY82P | |
| Controller | SIEMENS S7-300 / ET 200 M |
| - suitable I/O card | CPU 313C-2DP |
| CPU 314C-2DP | |
| CPU 314C-2PtP | |
| 6ES7 321-1BH02-0AA0 | |
| 6ES7 321-1BL00-0AA0 | |
| 6ES7 322-1BH01-0AA0 | |
| 6ES7 322-1BL00-0AA0 | |
| 6ES7 323-1BH01-0AA0 | |
| 6ES7 323-1BL00-0AA0 | |
| Controller | Schneider Electric Modicon TSX QUANTUM |
| - suitable I/O card | DDI 353 |
| DDI 853 | |
| DAI 353 | |
| DAI 453 | |
| DDO 353 |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Standards/regulations | IEC 60664 |
| DIN EN 50178 | |
| Rated surge voltage | 0.6 kV |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |