PHOENIX CONTACT PTI 4-L/L PTI 4-L/L 3214052 PHOENIX CONTACT Installation level terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PTI 4-L/L 3214052 PHOENIX CONTACT Installation level terminal block

PTI 4-L/L

3214052

PHOENIX CONTACT

50 Pcs.

Installation level terminal block Distribution floor terminal block, nominal voltage: 400 V, nominal current: 28 A, Push-in connection, 1., 2. and 3rd floor, Dimensioning section: 4 mm², cross-section: 0.2 mm² - 6 mm², Push-in connection, mounting class: NS 35/7.5, NS 35/15, color: gray Multi-storey installation terminal, rated voltage: 400 V, rated current: 28 A, Push-in connection, 1., 2. and 3. Flat, Dimensioning section: 4 mm2, Cross-section: 0.2 mm2 - 6 mm2, Push-in connection, mounting type: NS 35/7.5, NS 35/15, colour: grey

Automation > Multi level installation terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Installation level terminal block is widely used in electrical distribution enclosures to facilitate organized multi-conductor routing, circuit isolation, and power distribution for building automation systems. These modular blocks save valuable DIN rail space while ensuring reliable contact for complex control circuitry. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Connectable conductor cross section solid-core (EF007337): 0.2 mm²
  • Connectable conductor cross section multi-wired (EF007343): 0.2 mm²
  • Rated current In (EF008250): 28 A
  • Rated voltage (EF000228): 400 V
  • Width (EF000008): 6.15 mm
  • Height (EF000040): 114 mm
  • Depth (EF000049): 48.691344 mm
  • Closing plate required (EF002525): Yes
  • Basic colour (EF002671): Grey
  • PE-function (EF002672): No

More info

▲

Key Commercial Data

Orderkey3214052
Packing unit50 pc
Minimum order quantity50 pc
Catalog pagePage 103 (C-1-2017)
GTIN4046356817820
Weight per Piece (excluding packing)19.150 g
Custom tariff number85369010
Country of originPL (Poland)

General

Number of levels3
Number of connections4
Potentials2
Nominal cross section4 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Maximum load current32 A (with 6 mm² conductor cross section)
Rated surge voltage6 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition1.02 W (the value is multiplied when connecting multiple levels)
Maximum load current32 A (with 6 mm² conductor cross section)
Nominal current IN28 A (with 4 mm² conductor cross section)
Nominal voltage UN400 V
Open side panelYes
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width6.2 mm
End cover width2.2 mm
Length114 mm
Height NS 35/7,550.5 mm
Height NS 35/1558 mm

Connection data

Connection methodPush-in connection
Connection in acc. with standardIEC 60947-7-1
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.6 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible10
Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.4 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.1 mm²
Stripping length10 mm ... 12 mm
Internal cylindrical gageA4
Connection methodPush-in connection
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.1 mm²
Stripping length10 mm ... 12 mm

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.