View larger
PLC-OPT- 24DC/24DC/100KHZ-G 2902974 PHOENIX CONTACT Solid-state relay module
PLC-OPT-24DC/24DC/100KHZ-G
2902974
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The PLC-OPT- 24DC/24DC/100KHZ-G 2902974 PHOENIX CONTACT Solid-state relay module is engineered for high-frequency pulse transmission and galvanic signal isolation in automation and control systems. Optoelectronic coupling allows these modules to process rapid signal sequences reliably without mechanical wear.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2902974
- Packing unit: 1 pc
- Catalog page: Page 411 (C-5-2017)
- GTIN: 4046356702782
- Weight per Piece (excluding packing): 32.860 g
- Custom tariff number: 85364190
- Country of origin: DE (Germany)
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Width: 6.2 mm
- Height: 80 mm
- Depth: 86 mm
- Ambient temperature (operation): -20 °C ... 60 °C
- Ambient temperature (storage/transport): -25 °C ... 75 °C
- Degree of protection: IP20
- Nominal input voltage U N: 24 V DC
- Input voltage range in reference to U N: 0.8 ... 1.2
More info
▲Key Commercial Data
| Orderkey | 2902974 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 411 (C-5-2017) |
| GTIN | 4046356702782 |
| Weight per Piece (excluding packing) | 32.860 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 75 °C |
| Degree of protection | IP20 |
Input data
| Nominal input voltage UN | 24 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| Input voltage range | 19.2 V DC ... 28.8 V DC |
| Switching threshold "0" signal in reference to UN | < 0.4 |
| Switching threshold "1" signal in reference to UN | > 0.8 |
| Typical input current at UN | 8 mA |
| Typical response time | 1 µs |
| Typical turn-off time | 2 µs |
| Operating voltage display | Yellow LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Surge voltage protection | > 33 V |
| Transmission frequency | 100 kHz |
| Power dissipation for nominal condition | 0.19 W |
Output data
| Designation | Output data |
|---|---|
| Output voltage range | 14 V DC ... 30 V DC |
| Limiting continuous current | 50 mA |
| Quiescent current | 15 mA |
| Surge voltage protection | > 35 V |
| Voltage drop at max. limiting continuous current | < 2.2 V |
| Output circuit | 3-conductor push-pull, ground referenced |
| Type of protection | Reverse polarity protection |
| Surge protection |
Connection data 1
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
Connection data 2
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Test voltage input/output | 2.5 kVrms(50 Hz, 1 min.) |
|---|---|
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | DIN EN 50178 |
| Degree of pollution | 2 |
| Overvoltage category | II |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 50 V DC |
| Rated surge voltage | 0.5 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | II |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |