PHOENIX CONTACT MACX MCR-SL-RPSSI-I-SP MACX MCR-SL-RPSSI-I-SP 2924207 PHOENIX CONTACT Power/input isolating amplifier View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MACX MCR-SL-RPSSI-I-SP 2924207 PHOENIX CONTACT Power/input isolating amplifier

MACX MCR-SL-RPSSI-I-SP

2924207

PHOENIX CONTACT

1 Pcs.

Power/input isolating amplifier Input and power signal conditioner, with HART transparency. It transmits 0/4-20 mA powered or active signals at a load (active or passive). 3-way galvanic separation, SIL 2 according to IEC 61508.

Automation > Isolation amplifier
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Part number 2924207 from Phoenix Contact, the MACX MCR-SL-RPSSI-I-SP power/input isolating amplifier facilitates the secure transmission and isolation of analog signals in industrial measurement networks. Such isolating amplifiers are standard components in process automation engineering, acting to suppress electrical noise and decouple signal circuits to ensure dependable control system performance.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated supply voltage DC (EF007078): 19.2 V
  • Number of input ranges -60 mV ... +60 mV (EF006927): 0
  • Number of input ranges -100 mV ... +100 mV (EF006912): 0
  • Number of input ranges -300 mV ... +300 mV (EF006920): 0
  • Number of input ranges -500 mV ... +500 mV (EF006926): 0
  • Number of input ranges -1 V ... +1 V (EF006906): 0
  • Number of input ranges -2 V ... +2 V (EF006913): 0
  • Number of input ranges -2.5 V ... +2.5 V (EF006915): 0
  • Number of input ranges -5 V ... +5 V (EF006923): 0
  • Number of input ranges -10 V ... +10 V (EF006909): 0
  • Number of input ranges -20 V ... +20 V (EF006917): 0
  • Number of input ranges 0 mV ... 60 mV (EF006905): 0
  • Number of input ranges 0 mV ... 100 mV (EF006893): 0
  • Number of input ranges 0 mV ... 200 mV (EF006898): 0
  • Number of input ranges 0 mV ... 300 mV (EF006901): 0
  • Number of input ranges 0 mV ... 500 mV (EF006904): 0

More info

▲

Key Commercial Data

Orderkey2924207
Packing unit1 pc
Catalog pagePage 120 (C-5-2017)
GTIN4046356448338
Weight per Piece (excluding packing)132.210 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width12.5 mm
Height116 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.

Input data

Signal inputActive current input
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 21.5 V (20 mA)
> 20.8 V (24 mA)
Underload/overload signal range0 mA ... 24 mA (Extended transmission range for diagnostics)
Signal inputPassive current input
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop< 3.5 V (in input isolating amplifier operation)
Underload/overload signal range0 mA ... 24 mA (Extended transmission range for diagnostics)

Output data

Signal outputCurrent output (active and passive)
Current output signal4 mA ... 20 mA (active)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 22.5 mA (Cable short-circuit in the input)
Signal outputCurrent output (active and passive)
Current output signal0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

DesignationRepeater power supply operation
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption< 76 mA (24 V DC / 20 mA / 1000 )
Power dissipation< 1.1 W (24 V DC / 20 mA)
Power consumption< 1.8 W (20 mA / 1000 )
DesignationSignal conditioner operation
Nominal supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption< 44 mA (24 V DC / 20 mA / 1000 )
Power dissipation< 0.75 W (24 V DC / 20 mA / 1000 )

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Connection methodPush-in connection

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)< 200 µs (for jump 4 mA ... 20 mA, load 600 Ω)
< 600 µs (for jump 0 mA ... 20 mA, load 600 Ω)
Status displayGreen LED (supply voltage)
Flammability rating according to UL 94V0
Degree of pollution2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC directive
Housing materialPA 6.6-FR
Colorgray
DesignationInput/output/power supply
Electrical isolation300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEX II 3 G Ex nA II T4 Gc X
UL, USA/CanadaUL 61010 Listed
UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
SIL2

Data communication (bypass)

HART functionYes
Protocols supportedHART

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Flammability rating according to UL 94V0
ConformanceCE-compliant, additionally EN 61326
ATEX II 3 G Ex nA II T4 Gc X
UL, USA/CanadaUL 61010 Listed
UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCA
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.