Operating as a modular terminal block, the Phoenix Contact IB IL AO 4/8/U/BP-2MBD-PAC is an Inline terminal designed to distribute analog output signals across distributed automation networks. Such terminals integrate smoothly into backplane architectures to govern multiple control loops.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): No
- Input, resistance thermometer (EF003207): No
- Input, thermocouple (EF003208): No
- Input signal, configurable (EF003209): No
- Output, current (EF003212): No
- Output, voltage (EF003213): Yes
- Output signal configurable (EF003214): Yes
- Resolution of the analogue outputs (EF003577): 16 Bit
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 8
- Analogue inputs configurable (EF008518): No
- Analogue outputs configurable (EF008519): Yes
More info
▲Key Commercial Data
| Orderkey | 2878052 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 291 (AX-2009) |
| GTIN | 4046356048453 |
| Weight per Piece (excluding packing) | 215.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
Interfaces
| Designation | Inline local bus |
|---|---|
| No. of channels | 4 |
| Connection method | Inline data jumper |
| Transmission speed | 2 Mbps |
| Transmission physics | Copper |
Inline potentials
| Designation | Communications power (UL) |
|---|---|
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Current consumption | typ. 100 mA |
| max. 120 mA | |
| Designation | Supply of analog modules (UANA) |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 72 mA |
| max. 95 mA |
Analog outputs
| Number of outputs | 8 |
|---|---|
| Connection technology | 2-wire |
| Note regarding the connection technology | shielded |
| Output name | Analog outputs |
| D/A resolution | 16 bit |
| Type of protection | Transient protection of outputs |
| Data formats | IB IL, IB ST, IB RT, standardized representation, S7 compatible |
| Representation of output values | 16 bits (15 bits + sign) |
| Process data update | < 2 ms (depends on operating mode) |
| Load/output load current output | > 2 kΩ |
| Voltage output signal | 0 V ... 10 V |
| -10 V ... 10 V | |
| 0 V ... 5 V | |
| -5 V ... 5 V | |
| Load/output load voltage output | > 2 kΩ 0.05 % |
| Precision | typ. 0.1 % (of output range final value) |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |