PHOENIX CONTACT IB IL AI 2/SF-XC-PAC IB IL AI 2/SF-XC-PAC 2701157 PHOENIX CONTACT Inline terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL AI 2/SF-XC-PAC 2701157 PHOENIX CONTACT Inline terminal

IB IL AI 2/SF-XC-PAC

2701157

PHOENIX CONTACT

1 Pcs.

Inline terminal Inline, Analog input module, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, -20 mA... 20 mA, connection technology: 2 conductors, transmission rate on the local bus: 500 kBit/s, Extreme Conditions variant, protection rating: IP20, including inline connector and marking surface

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact IB IL AI 2/SF-XC-PAC is an Inline terminal designed to acquire analog input signals from industrial sensors and transducers, converting physical measurements into digital data for programmable logic controllers. Such terminal blocks form the backbone of distributed automation networks, ensuring reliable data acquisition.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Input, current (EF003204): Yes
  • Input, voltage (EF003205): Yes
  • Input, resistor (EF003206): No
  • Input, resistance thermometer (EF003207): No
  • Input, thermocouple (EF003208): No
  • Input signal, configurable (EF003209): Yes
  • Output, current (EF003212): No
  • Output, voltage (EF003213): No
  • Output signal configurable (EF003214): No
  • Number of analogue inputs (EF001994): 2
  • Number of analogue outputs (EF001995): 0
  • Analogue inputs configurable (EF008518): Yes
  • Analogue outputs configurable (EF008519): No
  • Number of HW-interfaces industrial Ethernet (EF003020): 0

More info

▲

Key Commercial Data

Orderkey2701157
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 158 (C-6-2017)
GTIN4046356713832
Weight per Piece (excluding packing)69.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width12.2 mm
Height136.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight69 g
Note on weight specificationswith connector
Operating modeProcess data operation with 2 words
Diagnostics messagesFailure of the internal I/O supply Yes
Peripheral fault Error message in the process data
User error Error message in the process data

Interfaces

DesignationInline local bus
No. of channels2
Connection methodInline data jumper
Transmission speed500 kbps

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current consumptiontyp. 45 mA
max. 60 mA
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 13 mA
max. 18 mA
Power consumptiontyp. 662 mW

Analog inputs

Description of the inputSingle-ended inputs, voltage or current
Input nameAnalog inputs
Number of inputs2
Connection methodInline shield connector
Connection technology2-wire
Note regarding the connection technologyshielded
A/D conversion timetyp. 120 µs (per channel)
Limit frequency (3 dB)40 Hz
Type of protectionSurge protection
Data formatsIB IL, IB ST, IB RT, standardized representation
Measuring principleSuccessive approximation
Measured value resolution16 bits (15 bits + sign bit)
Measured value representation16 bit two's complement
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Input resistance current input50 Ω (Shunt)
Voltage input signal0 V ... 10 V
-10 V ... 10 V
Input resistance of voltage input> 220 kΩ
Common mode voltage range signal - ground40 V (between current input and functional earth ground)

Electrical isolation

Test section7.5 V supply (bus logic), 24 V supply UANA/ I/O 500 V AC 50 Hz 1 min.
7.5 V supply (bus logic), 24 V supply UANA/functional earth ground 500 V AC 50 Hz 1 min.
I/O / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Connection in acc. with standardCUL
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.