View larger
IB IL TEMP 2 UTH-XC-PAC 2701216 PHOENIX CONTACT Inline terminal
IB IL TEMP 2 UTH-XC-PAC
2701216
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Inline terminal like the Phoenix Contact IB IL TEMP 2 UTH-XC-PAC serves as a modular I/O component in automated systems, specifically engineered to interface temperature sensors with a central control unit. These terminals process incoming signals from various industrial sensors to monitor thermal conditions across complex manufacturing machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): No
- Input, resistance thermometer (EF003207): No
- Input, thermocouple (EF003208): Yes
- Input signal, configurable (EF003209): No
- Output, current (EF003212): No
- Output, voltage (EF003213): No
- Output signal configurable (EF003214): No
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Analogue inputs configurable (EF008518): No
- Analogue outputs configurable (EF008519): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
More info
▲Key Commercial Data
| Orderkey | 2701216 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 164 (C-6-2017) |
| GTIN | 4046356727846 |
| Weight per Piece (excluding packing) | 105.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 12.2 mm |
| Height | 136.8 mm |
| Depth | 71.5 mm |
| Note on dimensions | Housing dimensions |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C (Standard) |
|---|---|
| -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 105 g |
| Note on weight specifications | with connector |
| Operating mode | Process data operation with 2 words |
| Diagnostics messages | Failure of the internal I/O supply I/O error message sent to the bus coupler |
| Failure of or insufficient communications power ULI/O error message sent to the bus coupler | |
| Peripheral fault Error message in the process data | |
| User error Error message in the process data |
Interfaces
| Designation | Inline local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kbps |
Inline potentials
| Designation | Communications power (UL) |
|---|---|
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Current consumption | typ. 43 mA |
| max. 60 mA | |
| Designation | Supply of analog modules (UANA) |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 11 mA |
| max. 18 mA | |
| Power consumption | typ. 587 mW |
Analog inputs
| Number of inputs | 2 (Thermocouples or linear voltage) |
|---|---|
| Input name | Analog UTH inputs |
| Description of the input | Inputs for thermocouples or linear voltage |
| Connection method | Inline connector |
| Connection technology | 2-wire |
| Note regarding the connection technology | Shielded compensating line for TC with encapsulated sensors |
| Sensor types that can be used (TC) | U, T, L, J, E, K, N, S, R, B, C, W, HK |
| Measuring principle | Successive approximation |
| Measured value representation | 16 bits (15 bits + sign bit) |
| A/D conversion time | typ. 120 µs (per channel) |
| Process data update | max. 30 ms (For both channels) |
| Type of protection | Surge protection (TC channels) |
Electrical isolation
| Test section | 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min. |
|---|---|
| 7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min. | |
| 24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min. |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |