View larger
IB IL TEMP 2 RTD-XC-PAC 2701217 PHOENIX CONTACT Inline function terminal
IB IL TEMP 2 RTD-XC-PAC
2701217
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Harsh industrial applications often require specialized monitoring equipment, and an Inline function terminal delivers reliable signal conditioning for temperature sensors in extreme conditions. Manufactured by Phoenix Contact under product number IB IL TEMP 2 RTD-XC-PAC, this hardware ensures stable data acquisition for industrial processes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): Yes
- Input, resistance thermometer (EF003207): Yes
- Input, thermocouple (EF003208): No
- Input signal, configurable (EF003209): No
- Resolution of the analogue inputs (EF003575): 16 Bit
- Output, current (EF003212): No
- Output, voltage (EF003213): No
- Output signal configurable (EF003214): No
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Analogue inputs configurable (EF008518): No
- Analogue outputs configurable (EF008519): No
More info
▲Key Commercial Data
| Orderkey | 2701217 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 165 (C-6-2017) |
| GTIN | 4046356728829 |
| Weight per Piece (excluding packing) | 67.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C (Standard) |
|---|---|
| -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 67 g |
| Note on weight specifications | with connector |
| Operating mode | Process data operation with 2 words |
Interfaces
| Designation | Inline local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kbps |
Inline potentials
| Designation | Communications power (UL) |
|---|---|
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Current consumption | typ. 43 mA |
| max. 60 mA | |
| Designation | Supply of analog modules (UANA) |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 11 mA |
| max. 18 mA | |
| Power consumption | typ. 587 mW |
Analog inputs
| Number of inputs | 2 |
|---|---|
| Input name | Analog RTD inputs |
| Description of the input | Input for resistive temperature sensors |
| Connection method | Spring-cage connection |
| Connection technology | 2, 3, 4-wire |
| Note regarding the connection technology | shielded |
| Sensor types (RTD) that can be used | Pt, Ni, KTY, Cu sensors, linear resistors |
| Linear resistance measuring range | 0 Ω ... 400 Ω |
| 0 Ω ... 4 kΩ | |
| Measuring principle | Successive approximation |
| Measured value representation | 16 bits two's complement and other |
| A/D conversion time | typ. 120 µs (per channel) |
| Resolution A/D | 16 bit (15 bit + sign bit) |
| Process data update | 32 ms (both channels with 3-wire technology) |
Electrical isolation
| Test section | 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min. |
|---|---|
| 7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min. | |
| 24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min. |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |