PHOENIX CONTACT IB IL TEMP 2 RTD-PAC IB IL TEMP 2 RTD-PAC 2861328 PHOENIX CONTACT Inline function terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL TEMP 2 RTD-PAC 2861328 PHOENIX CONTACT Inline function terminal

IB IL TEMP 2 RTD-PAC

2861328

PHOENIX CONTACT

1 Pcs.

Inline function terminal Inline, Temperature recording module, Analogue RTD inputs: 2, connection technology: 2, 3, 4 conductors, transmission speed on local bus: 500 kBit/s, protection rating: IP20, including Inline connector and marking surface

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An inline function terminal like the Phoenix Contact IB IL TEMP 2 RTD-PAC is integrated into modular automation stations to condition and process specialist signals from temperature probes and industrial sensors. These units translate physical measurements into standardized digital data for centralized programmable logic controllers.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Input, current (EF003204): No
  • Input, voltage (EF003205): No
  • Input, resistor (EF003206): Yes
  • Input, resistance thermometer (EF003207): Yes
  • Input, thermocouple (EF003208): No
  • Input signal, configurable (EF003209): No
  • Resolution of the analogue inputs (EF003575): 16 Bit
  • Output, current (EF003212): No
  • Output, voltage (EF003213): No
  • Output signal configurable (EF003214): No
  • Number of analogue inputs (EF001994): 0
  • Number of analogue outputs (EF001995): 0
  • Analogue inputs configurable (EF008518): No
  • Analogue outputs configurable (EF008519): No

More info

▲

Key Commercial Data

Orderkey2861328
Packing unit1 pc
Catalog pagePage 165 (C-6-2017)
GTIN4017918894269
Weight per Piece (excluding packing)67.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width12.2 mm
Height136.8 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
80 kPa ... 106 kPa (up to 3000 m above sea level, in ATEX Zone 2)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight67 g
Note on weight specificationswith connector
Operating modeProcess data operation with 2 words
Diagnostics messagesFailure of the internal I/O supply I/O error message sent to the bus coupler
Failure of or insufficient communications power ULI/O error message sent to the bus coupler
Peripheral fault Error message in the process data
User error Error message in the process data

Interfaces

DesignationInline local bus
No. of channels2
Connection methodInline data jumper
Transmission speed500 kbps

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current consumptiontyp. 43 mA
max. 60 mA
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 11 mA
max. 18 mA
Power consumptiontyp. 587 mW

Analog inputs

Number of inputs2
Input nameAnalog RTD inputs
Description of the inputInput for resistive temperature sensors
Connection methodSpring-cage connection
Connection technology2, 3, 4-wire
Note regarding the connection technologyshielded
Sensor types (RTD) that can be usedPt, Ni, KTY, Cu sensors, linear resistors
Linear resistance measuring range0 Ω ... 400 Ω
0 Ω ... 4 kΩ
Measuring principleSuccessive approximation
Measured value representation16 bit two's complement
A/D conversion timetyp. 120 µs (per channel)
Resolution A/D16 bit
Process data update32 ms (both channels with 3-wire technology)

Electrical isolation

Test section7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min.
7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min.
24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Connection in acc. with standardCUL
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.