Functioning as an interface terminal, the IB IL UTH 4/K-ECO 2702503 PHOENIX CONTACT Inline function terminal connects thermocouple sensors directly to modular automation nodes. Such units provide necessary signal conditioning to monitor elevated temperatures across demanding manufacturing environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): No
- Input, resistance thermometer (EF003207): No
- Input, thermocouple (EF003208): Yes
- Input signal, configurable (EF003209): No
- Resolution of the analogue inputs (EF003575): 24 Bit
- Output, current (EF003212): No
- Output, voltage (EF003213): No
- Output signal configurable (EF003214): No
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Analogue inputs configurable (EF008518): No
- Analogue outputs configurable (EF008519): No
More info
▲Key Commercial Data
| Orderkey | 2702503 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 143 (C-6-2017) |
| GTIN | 4055626206080 |
| Weight per Piece (excluding packing) | 69.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | 0 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 69 g |
| Note on weight specifications | with connector |
| Diagnostics messages | Failure of the internal I/O supply I/O error message sent to the bus coupler |
| Checksum error I/O error message sent to the bus coupler |
Interfaces
| Designation | Inline local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Inline data jumper |
| Transmission speed | 500 kbps |
Inline potentials
| Designation | Communications power (UL) |
|---|---|
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Current consumption | typ. 38 mA |
| max. 55 mA | |
| Designation | Supply of analog modules (UANA) |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 32 mA |
| max. 39 mA | |
| Power consumption | typ. 1.05 W (total) |
Analog inputs
| Number of inputs | 4 (type K) |
|---|---|
| Input name | Analog UTH inputs |
| Description of the input | Differential inputs |
| Connection method | Inline connector |
| Connection technology | 2-wire |
| Note regarding the connection technology | shielded |
| Sensor types that can be used (TC) | K |
| Measuring principle | Sigma/Delta process |
| Measured value representation | 16 bits (15 bits + sign bit) |
| A/D conversion time | typ. 120 ms |
| Resolution A/D | 24 bit |
| Process data update | < 10 ms |
| Type of protection | Transient protection of inputs |
Electrical isolation
| Test section | Bus logic (local bus, communications power) 500 V AC 50 Hz 1 min. |
|---|---|
| Analog I/O 500 V AC 50 Hz 1 min. | |
| Functional earth ground 500 V AC 50 Hz 1 min. |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |