View larger
IB IL SGI 2/P/EF-PAC 2702373 PHOENIX CONTACT Inline function terminal
IB IL SGI 2/P/EF-PAC
2702373
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact inline function terminal type IB IL SGI 2/P/EF-PAC (listed as IB IL SGI 2/P/EF-PAC 2702373 PHOENIX CONTACT Inline function terminal) provides specialized signal conditioning capabilities within distributed automation networks. It is deployed to connect complex measurement elements to a modular controller system, ensuring reliable data integration on the plant floor.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): No
- Input, resistance thermometer (EF003207): No
- Input, thermocouple (EF003208): No
- Input signal, configurable (EF003209): No
- Output, current (EF003212): No
- Output, voltage (EF003213): No
- Output signal configurable (EF003214): No
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Analogue inputs configurable (EF008518): No
- Analogue outputs configurable (EF008519): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
More info
▲Key Commercial Data
| Orderkey | 2702373 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 163 (C-6-2017) |
| GTIN | 4055626228464 |
| Weight per Piece (excluding packing) | 249.130 g |
| Custom tariff number | 85389099 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 249.13 g |
| Operating mode | Process data operation with 3 words, PCP with 1 word |
| Diagnostics messages | Failure of the power supply at UANAError message in the process data |
| Failure of or insufficient communications power ULI/O error message sent to the bus coupler | |
| Peripheral fault Error message in the process data |
Interfaces
| Designation | Inline local bus |
|---|---|
| Connection method | Inline data jumper |
| Transmission speed | 500 kbps |
| Transmission physics | Copper |
Inline potentials
| Designation | Communications power (UL) |
|---|---|
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Current consumption | typ. 80 mA |
| max. 95 mA | |
| Designation | Supply of analog modules (UANA) |
| Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | 14 mA (for no-load operation without strain gauge or display) |
| typ. 32 mA (in case of typical load of 350 Ohm per channel) | |
| 115 mA (with maximum load of 43 Ω and display) | |
| Power consumption | typ. 1.4 W (Device in nominal operation) |
Analog inputs
| Description of the input | Input channels for strain gauge |
|---|---|
| Number of inputs | 2 |
| Connection technology | 6 or 4-wire, twisted pair shielded cable |
| Bridge difference Ud | Measuring range specified by selecting the characteristic |
| Bridge voltage U0 | 5 V |
| Characteristics | ±1 mV/V, ±2 mV/V, ±3 mV/V, ±3.33 mV/V, ±4 mV/V, ±5 mV/V, ±6 mV/V, manual characteristic value specification |
| Measured value representation | 16 bit, 20 bit, ASCII data record |
Analog outputs
| Output description | Jumper supply |
|---|---|
| Number of outputs | 2 |
| Impedance | > 43 Ω (per channel) |
| Output voltage | typ. 5 V |
| Output current | max. 115 mA (per channel) |
Electrical isolation
| Test section | Logic 500 V AC 50 Hz 1 min. |
|---|---|
| Analog I/O 500 V AC 50 Hz 1 min. | |
| RS-485 500 V AC 50 Hz 1 min. | |
| N/O contact Ka1- Kb1500 V AC 50 Hz 1 min. | |
| N/O contact Ka2- Kb2500 V AC 50 Hz 1 min. | |
| Functional earth ground 500 V AC 50 Hz 1 min. |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |