PHOENIX CONTACT IB IL CNT-PAC/10 IB IL CNT-PAC/10 2897046 PHOENIX CONTACT Module counter compact View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL CNT-PAC/10 2897046 PHOENIX CONTACT Module counter compact

IB IL CNT-PAC/10

2897046

PHOENIX CONTACT

10 Pcs.

Module counter compact Inline, Counter input for 24 V signals: 1, Control input for 24 V signals: 1, Switching output: 1, 24 V DC, 0.5 A, transmission rate on the local bus: 500 kBit/s, protection index: IP20

Automation > Fieldbus, decentr. periphery - function-/technology module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The IB IL CNT-PAC/10 2897046 PHOENIX CONTACT Module counter compact serves as a modular input device designed to register high-frequency event pulses and measure operational cycles in industrial equipment. Compact counter units are frequently deployed in automated processing lines for batch counting, frequency measurement, and position tracking. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of functions (EF003244): 1
  • Number of HW-interfaces industrial Ethernet (EF003020): 0
  • Number of interfaces PROFINET (EF006932): 0
  • Number of HW-interfaces RS-232 (EF003021): 0
  • Number of HW-interfaces RS-422 (EF003022): 0
  • Number of HW-interfaces RS-485 (EF003023): 0
  • Number of HW-interfaces serial TTY (EF003024): 0
  • Number of HW-interfaces parallel (EF003026): 0
  • Number of HW-interfaces wireless (EF006933): 0
  • Number of HW-interfaces USB (EF003025): 0
  • Number of HW-interfaces other (EF003027): 0
  • With optical interface (EF003028): No
  • Supporting protocol for EtherCAT (EF017564): No
  • Supporting protocol for TCP/IP (EF003050): No
  • Supporting protocol for PROFIBUS (EF003052): Yes
  • Supporting protocol for CAN (EF003053): No

More info

Commercial data

Order key2897046
Packaging unit10 pcs
Sell keyDRI163 -
Minimum Order Quantity10 pcs
Ean4046356139021
Weight per unit (excluding packaging)130,000 g
Tariff rate number85389091
Country of originDE (Germany)

Observation

Restriction of UseEMC: Class A product, see manufacturer's declaration in the download center

Environmental conditions

Ambient Temperature (Service)-25°C ... 55 °C
Ambient Temperature (Storage/Transport)-25 °C ... 85 °C
Permissible air humidity (service)10 % ... 95 % (according to DIN EN 61131-2)
Permissible air humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air Pressure (Service)70 kPa... 106 kPa (up to 3000 m above NN)
Air Pressure (Storage/Transport)70 kPa... 106 kPa (up to 3000 m above NN)
Protection IndexIP20

General

Type of mountingRail
net weight130 g
Observation about weight indicationswith connectors
Operating ModeProcess Data Service with Two Words
Diagnostic messagesShort circuit of sensor power
Overloading the sensor power supply

Interfaces

DenominationBus local Inline
Connection typeInline data handling
Transmission speed500 kBit/s
Transmission Physicscopper

Inline Potentials

DenominationLogic Supply (UL)
Supply voltage7.5 V DC (via potential maneuver)
Current absorptiontyp. 40 mA
max. 50 mA
Power Consumptionmax. 0.375 W (to UL)
DenominationSegment Circuit Power (U)s)
Supply voltage24 V DC (via potential maneuver)
Current absorptionmax. 1 A

Counter Inputs

Denomination EntryCounter input for 24 V signals
Number of Entries1 (only one counter input can be used, either for 24 V or 5 V signals)
Connection typeSpring-loaded connection
Operating ModeEvent counting, frequency/time measurement
Input voltage24 V DC
30 V DC (maximum)
Input Voltage Range Signal "0"0 V DC ... 5 V DC
Input Voltage Range Signal "1"15 V DC ... 30 V DC
Input Frequencymax. 100 kHz
Input currenttyp. 5 mA
Denomination EntryCounter input for 5 V signals
Number of Entries1 (only one counter input can be used, either for 24 V or 5 V signals)
Connection typeSpring-loaded connection
Connection technology2 wires (shielded), 5V external power supply
Operating ModeEvent counting, frequency/time measurement
Input voltage5 V DC (Rated Voltage)
8 V DC (maximum)
Input Voltage Range Signal "0"0 V ... 1.5 V
Input Voltage Range Signal "1"3.5 V ... 8 V
Input Frequencymax. 100 kHz
Input currenttyp. 5 mA
Input resistanceapprox. 1.7 kΩ

Digital outputs

Denomination OutputSwitching Output
Connection typeSpring-loaded connection
Connection technology2 conductors
Number of outputs1
Name of protectionShort Circuit Protection
Overload protection
Output voltage24 V DC (Rated Voltage)
Output currentmax. 0.5 A (Rated Current)
Inductive Rated Loadmax. 12 VA (1.2 H, 48 Ω)
Nominal lamp loadmax. 12 W
Resistive Load Ratingmax. 12 W (48 Ω)

Standards & Specifications

Kind of protectionIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSTime slot for intended use: unlimited = EFUP-e
No hazardous substances above thresholds

Classifications

eCl@ss

eCl@ss 4.027250304
eCl@ss 4.127250304
eCl@ss 5.027250304
eCl@ss 5.127242605
eCl@ss 6.027242605
eCl@ss 7.027242605
eCl@ss 8.027242605
eCl@ss 9.027242605

ETIM

ETIM 2.0EC001433
ETIM 3.0EC001601
ETIM 4.0EC001601
ETIM 5.0EC001601
ETIM 6.0EC001601

UNSPSC

UNSPSC 6.0143172015
UNSPSC 7.090143201404
UNSPSC 1143172015
UNSPSC 12.0143201404
UNSPSC 13.243201404

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.