PHOENIX CONTACT IB IL 24 PSDO 4/4-R-PAC IB IL 24 PSDO 4/4-R-PAC 2700804 PHOENIX CONTACT Safety module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL 24 PSDO 4/4-R-PAC 2700804 PHOENIX CONTACT Safety module

IB IL 24 PSDO 4/4-R-PAC

2700804

PHOENIX CONTACT

1 Pcs.

Safety module Safety input/output components, digital output module with 4 safe positive and negative connection outputs; for the SafetyBridge, PROFIsafe and INTERBUS-Safety system; to SIL 3, Cat. 4/PL e, SIL 3, spring-loaded plug-in connection with discharge connectors

Automation > Fieldbus, decentr. periphery - digital I/O module
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Serving as a safety module, the Phoenix Contact IB IL 24 PSDO 4/4-R-PAC manages critical safety-related control functions and secure signal processing in industrial automation systems. Such devices monitor emergency stops and protective interlocks to safely shut down machine sections when hazards occur. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Number of digital inputs (EF001992): 0
  • Number of digital outputs (EF001993): 4
  • Digital inputs configurable (EF008516): No
  • Digital outputs configurable (EF008520): No
  • Type of voltage (input voltage) (EF003033): DC
  • Output current (EF003202): 2 A
  • Permitted voltage at output (EF007553): 24 V
  • Short-circuit protection, outputs available (EF003203): Yes
  • Number of HW-interfaces industrial Ethernet (EF003020): 0
  • Number of interfaces PROFINET (EF006932): 0
  • Number of HW-interfaces RS-232 (EF003021): 0
  • Number of HW-interfaces RS-422 (EF003022): 0
  • Number of HW-interfaces RS-485 (EF003023): 0
  • Number of HW-interfaces serial TTY (EF003024): 0

More info

▲

Key Commercial Data

Orderkey2700804
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4046356657402
Weight per Piece (excluding packing)421.900 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width48.8 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Permissible humidity (storage/transport)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Air pressure (operation)80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Degree of protectionIP20

Interfaces

DesignationInline local bus
No. of channels2
Connection methodInline data jumper
Transmission speed500 kbps / 2 Mbps

Digital outputs

Output nameDigital outputs
Output description+/- switching
Connection methodSpring-cage connection
Connection technology2, 3, 4-wire
Number of outputs4 (for two-channel assignment, +/- switching)
4
Type of protectionOverload protection, short-circuit protection of outputs
Output voltage24 V DC (US- 1 V)
Nominal output voltage24 V DC
Output currentmax. 3 A (Total current of all outputs)
Maximum output current per channel2 A
Maximum output current per module3 A (See technical data)

Power supply for module electronics

Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC

General

Mounting typeDIN rail
Net weight421.9 g
Note on weight specificationswith connectors
Diagnostics messagesShort-circuit / overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (see safety data)
Current consumptionmax. 230 mA
DesignationMain circuit supply (UM)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 30 mA (all outputs set including actuator current)
max. 3.03 A
DesignationSegment circuit supply (US)
Supply voltage24 V

Safety-related characteristic data

DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)max. 3 (two channel; dependent in parameterization and wiring)
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)max. 3 (two channel; dependent in parameterization and wiring)
DesignationEN ISO 13849
Performance level (PL)max. e (two channel; dependent in parameterization and wiring)
Categorymax. 4 (two channel; dependent in parameterization and wiring)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)max. 3 (two channel; dependent in parameterization and wiring)

Standards and Regulations

Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.