PHOENIX CONTACT IB IL 24 LPSDO 8 V3-PAC IB IL 24 LPSDO 8 V3-PAC 2701625 PHOENIX CONTACT Safety module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL 24 LPSDO 8 V3-PAC 2701625 PHOENIX CONTACT Safety module

IB IL 24 LPSDO 8 V3-PAC

2701625

PHOENIX CONTACT

1 Pcs.

Safety module Safety-oriented digital output module, IP20 degree of protection, for the SafetyBridge system. The module has 4 secure digital outputs with two-channel occupancy or 8 secure digital outputs with single-channel occupancy

Automation > Fieldbus, decentr. periphery - digital I/O module
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An IB IL 24 LPSDO 8 V3-PAC 2701625 PHOENIX CONTACT Safety module is deployed in automated manufacturing safety chains to safely interrupt power to hazardous machine zones when a fault condition occurs. Safety I/O islands integrate directly with standard controller racks to monitor emergency stops, light curtains, and safety interlocks.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Number of digital inputs (EF001992): 0
  • Number of digital outputs (EF001993): 4
  • Digital inputs configurable (EF008516): No
  • Digital outputs configurable (EF008520): No
  • Type of voltage (input voltage) (EF003033): DC
  • Output current (EF003202): 2 A
  • Permitted voltage at output (EF007553): 24 V
  • Short-circuit protection, outputs available (EF003203): Yes
  • Number of HW-interfaces industrial Ethernet (EF003020): 0
  • Number of interfaces PROFINET (EF006932): 0
  • Number of HW-interfaces RS-232 (EF003021): 0
  • Number of HW-interfaces RS-422 (EF003022): 0
  • Number of HW-interfaces RS-485 (EF003023): 0
  • Number of HW-interfaces serial TTY (EF003024): 0

More info

▲

Key Commercial Data

Orderkey2701625
Packing unit1 pc
Catalog pagePage 296 (C-6-2017)
GTIN4046356770033
Weight per Piece (excluding packing)355.200 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width48.8 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Permissible humidity (storage/transport)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Air pressure (operation)80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Degree of protectionIP20

Interfaces

DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kbps / 2 Mbps (can be switched)

Digital outputs

Output nameDigital outputs
Connection methodSpring-cage connection
Connection technology2, 3, 4-wire
Number of outputs4 (with two-channel assignment)
8
Type of protectionOverload protection, short-circuit protection of outputs
Output voltage24 V DC (US- 1 V)
Nominal output voltage24 V DC
Output currentmax. 6 A (Total current of all outputs, -25 °C ... 50 °C)
max. 4 A (Total current of all outputs, >50 °C ... 55 °C)
Maximum output current per channel2 A
Maximum output current per group3 A
Nominal load, inductivesee safety data
Nominal load, lampsee safety data
Nominal load, ohmicsee safety data

Power supply for module electronics

Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC

General

Mounting typeDIN rail
Net weight355.2 g
Note on weight specificationswith connectors
Diagnostics messagesShort-circuit / overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (see safety data)
Current consumptionmax. 230 mA (see safety data)
DesignationMain circuit supply (UM)
Supply voltage24 V DC (see safety data)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 30 mA (all outputs set including actuator current)
max. 6.03 A
DesignationSegment circuit supply (US)
Supply voltage24 V (see safety data)

SafetyBridge properties

Connection to I/O modulesmax. 16 (safe digital I/O modules)
Logic memory60 kByte

Safety-related characteristic data

DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)max. 3 (two channel; dependent in parameterization and wiring)
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)max. 3 (two channel; dependent in parameterization and wiring)
DesignationEN ISO 13849
Performance level (PL)max. e (two channel; dependent in parameterization and wiring)
Categorymax. 4 (two channel; dependent in parameterization and wiring)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)max. 3 (two channel; dependent in parameterization and wiring)

Standards and Regulations

Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.