View larger
PTPOWER 50 P 3260065 PHOENIX CONTACT High-current terminal block
PTPOWER 50 P
3260065
PHOENIX CONTACT
10 Pcs.
Automation > Feed-through terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact PTPOWER 50 P high-current terminal block provides a dependable connection interface for heavy-duty power feeds within industrial automation cabinets and heavy-load distribution systems. High-current terminal blocks are essential for safely terminating large industrial cables and maintaining structural circuit integrity under heavy operational loads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: High current terminal block
- Number of positions: 1
- Number of connections: 2
- Number of rows: 1
- Potentials: 1
- Data management status Article revision: 09
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Rated surge voltage: 8 kV
- Maximum power dissipation for nominal condition: 4.73 W
- Number of connections per level: 2
- Nominal cross section: 50 mm²
- Rated cross section AWG: 2/0
- 1 level Stripping length: 30 mm ... 32 mm
- Internal cylindrical gage: A10
- Connection in acc. with standard: IEC 60947-7-1
More info
▲| Product type | High current terminal block |
| Number of positions | 1 |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data management status | |
| Article revision | 09 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 8 kV |
| Maximum power dissipation for nominal condition | 4.73 W |
| Number of connections per level | 2 |
| Nominal cross section | 50 mm² |
| Rated cross section AWG | 2/0 |
| 1 level | |
| Stripping length | 30 mm ... 32 mm |
| Internal cylindrical gage | A10 |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section rigid | 10 mm² ... 70 mm² |
| Cross section AWG | 6 ... 2/0 (converted acc. to IEC) |
| Conductor cross section flexible | 10 mm² ... 70 mm² |
| Conductor cross section, flexible [AWG] | 6 ... 2/0 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 10 mm² ... 50 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, rigid | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, flexible | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, flexible, with ferrule without plastic sleeve | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, flexible, with ferrule with plastic sleeve | 10 mm² ... 50 mm² |
| Nominal current | 150 A |
| Maximum load current | 150 A (with 50 mm² conductor cross section) |
| Nominal voltage | 1000 V |
| 1 level Connection cross sections directly pluggable | |
| Conductor cross section rigid | 10 mm² ... 70 mm² |
| Conductor cross section, rigid [AWG] | 8 ... 2/0 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 10 mm² ... 50 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 10 mm² ... 50 mm² |
| Rated data (ATEX/IECEx) | |
| Identification | II 2 GD Ex eb IIC Gb |
| Operating temperature range | -60 °C ... 110 °C |
| Ex-certified accessories | 1206612 SZF 3-1,0X5,5 |
| 1201662 E/AL-NS 35 | |
| List of bridges | / EB 2-20/PT / 3260067 |
| / EB 3-20/PT / 3260068 | |
| Bridge data | 131 A / 50 mm² |
| Ex temperature increase | 40 K (147 A / 50 mm²) |
| Rated voltage | 1100 V |
| at bridging with insertion bridge | 1100 V |
| Rated insulation voltage | 1000 V |
| output | (Permanent) |
| Ex level General | |
| Rated current | 134 A |
| Maximum load current | 134 A |
| Contact resistance | 0.16 mΩ |
| Ex connection data General | |
| Ferrule length | 30 mm ... 32 mm |
| Stripping length | 30 mm |
| Nominal cross section | 50 mm² |
| Rated cross section AWG | 1/0 |
| Connection capacity rigid | 10 mm² ... 70 mm² |
| Connection capacity AWG | 8 ... 2/0 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 50 mm² |
| Width | 20 mm |
| Height | 101 mm |
| Depth on NS 35/15 | 105 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Mechanical data | |
| Open side panel | No |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection in acc. with standard | IEC 60947-7-1 |
| Mounting type | NS 35/15 |