PTPOWER 50-F 3260061 PHOENIX CONTACT High-current terminal block
PTPOWER 50-F
3260061
PHOENIX CONTACT
10 Pcs.
Automation > Feed-through terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PTPOWER 50-F high-current terminal block provides reliable, heavy-duty power distribution for demanding industrial energy management systems and large electrical drives. These specialized terminal blocks accommodate thick cables to securely handle massive electrical loads within heavy industrial switchgear. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: High current terminal block
- Number of positions: 1
- Pitch: 20 mm
- Number of connections: 2
- Number of rows: 1
- Potentials: 1
- Data management status Article revision: 08
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Rated surge voltage: 8 kV
- Maximum power dissipation for nominal condition: 4.73 W
- Number of connections per level: 2
- Nominal cross section: 50 mm²
- Rated cross section AWG: 2/0
- 1 level Stripping length: 30 mm ... 32 mm
- Internal cylindrical gage: A10
More info
▲| Product type | High current terminal block |
| Number of positions | 1 |
| Pitch | 20 mm |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data management status | |
| Article revision | 08 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 8 kV |
| Maximum power dissipation for nominal condition | 4.73 W |
| Number of connections per level | 2 |
| Nominal cross section | 50 mm² |
| Rated cross section AWG | 2/0 |
| 1 level | |
| Stripping length | 30 mm ... 32 mm |
| Internal cylindrical gage | A10 |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section rigid | 10 mm² ... 70 mm² |
| Cross section AWG | 6 ... 2/0 (converted acc. to IEC) |
| Conductor cross section flexible | 10 mm² ... 70 mm² |
| Conductor cross section, flexible [AWG] | 6 ... 2/0 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 10 mm² ... 50 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, rigid | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, flexible | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, flexible, with ferrule without plastic sleeve | 10 mm² ... 50 mm² |
| Cross-section with insertion bridge, flexible, with ferrule with plastic sleeve | 10 mm² ... 50 mm² |
| Nominal current | 150 A |
| Maximum load current | 150 A (with 50 mm² conductor cross section) |
| Nominal voltage | 1000 V |
| 1 level Connection cross sections directly pluggable | |
| Conductor cross section rigid | 10 mm² ... 70 mm² |
| Conductor cross section, rigid [AWG] | 8 ... 2/0 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 10 mm² ... 50 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 10 mm² ... 50 mm² |
| Rated data (ATEX/IECEx) | |
| Identification | II 2 GD Ex eb IIC Gb |
| Operating temperature range | -60 °C ... 110 °C |
| Ex-certified accessories | 1206612 SZF 3-1,0X5,5 |
| 1201662 E/AL-NS 35 | |
| List of bridges | / EB 2-20/PT / 3260067 |
| / EB 3-20/PT / 3260068 | |
| Bridge data | 131 A / 50 mm² |
| Ex temperature increase | 40 K (147 A / 50 mm²) |
| Rated voltage | 1100 V |
| at bridging with insertion bridge | 1100 V |
| Rated insulation voltage | 1000 V |
| output | (Permanent) |
| Ex level General | |
| Rated current | 134 A |
| Maximum load current | 134 A |
| Contact resistance | 0.16 mΩ |
| Ex connection data General | |
| Ferrule length | 30 mm ... 32 mm |
| Stripping length | 30 mm |
| Nominal cross section | 50 mm² |
| Rated cross section AWG | 1/0 |
| Connection capacity rigid | 10 mm² ... 70 mm² |
| Connection capacity AWG | 8 ... 2/0 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 50 mm² |
| Dimensional drawing | |
| Width | 20 mm |
| Height | 136.1 mm |
| Depth | 96 mm |
| Drill hole spacing | 123.4 mm |
| Hole diameter | 6.5 mm |
| Pitch | 20 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Surge voltage test | |
| Test voltage setpoint | 9.8 kV |
| Result | Test passed |
| Temperature-rise test | |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K |
| Result | Test passed |
| Short-time withstand current 50 mm² | 6 kA |
| Result | Test passed |
| Power-frequency withstand voltage | |
| Result | Test passed |
| Mechanical data | |
| Open side panel | No |
| Technical data | |
| Drill hole spacing | 123.4 mm |
| Mechanical strength | |
| Result | Test passed |
| Attachment on the carrier | |
| Test force setpoint | 10 N |
| Result | Test passed |
| Test for conductor damage and slackening | |
| Rotation speed | 10 rpm |
| Revolutions | 135 |
| Conductor cross section/weight | 10 mm² / 2 kg |
| 50 mm² / 9.5 kg | |
| 70 mm²/10.4 kg | |
| Result | Test passed |
| Aging | |
| Temperature cycles | 192 |
| Result | Test passed |
| Needle-flame test | |
| Time of exposure | 30 s |
| Result | Test passed |
| Oscillation/broadband noise | |
| Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Spectrum | Service life test category 2, bogie-mounted |
| Frequency | f1= 5 Hz to f2= 250 Hz |
| ASD level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test directions | X-, Y- and Z-axis |
| Result | Test passed |
| Shocks | |
| Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Pulse shape | Half-sine |
| Acceleration | 30g |
| Shock duration | 18 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Result | Test passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection in acc. with standard | IEC 60947-7-1 |
| Mounting type | direct screw connection |