View larger
HC-BB46-I-CT-F 1584758 PHOENIX CONTACT HEAVYCON socket insert, series: BB46, 46-pos., crimp connection, with..
HC-BB46-I-CT-F
1584758
PHOENIX CONTACT
1 Pcs.
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-density applications, the Phoenix Contact HC-BB46-I-CT-F socket insert provides a robust internal connection hub for heavy-duty industrial connector assemblies. Contact inserts securely organize dozens of circuit paths inside protective hoods and housings to safeguard complex automation wiring.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of power contacts (EF012216): 46
- Number of control contacts (EF012217): 0
- Contact insert without contacts (EF007324): Yes
- Contact type (EF001587): Bus
- Number of poles (EF001391): 46
- Diameter plug-in contact (EF007320): 2.5 mm
- Material connector insert (EF007545): Thermoplastic
- Rated current In (EF008250): 16 A
- Ambient temperature (EF002386): 125 °C
- Operating temperature (EF002393): -40 °C
- Rated voltage (EF000228): 500 V
- Rated surge voltage (EF002993): 6 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 3
- Type of electric connection (EF003961): Crimp connection
- With wire protection (EF000550): No
More info
▲General
| Note | For HC-B24 housing, crimp contacts CK 2,5-ED (crimp contacts not included in scope of supply) |
|---|---|
| Connection method | Crimp connection |
| Pollution degree | 3 |
| Overvoltage category | III |
| Number of positions | 46+PE |
| Insertion/withdrawal cycles | ≥ 500 |
| Type | B24 |
| Connection in acc. with standard | IEC / EN |
| Conductor cross section | 0.5 mm² ... 4 mm² |
| Connection cross section AWG | 20 ... 12 |
| Stripping length of the individual wire | 7.5 mm |
| Assembly instructions | - Housing heights of h ≥ 72 mm are recommended when there is a high number of wires. |
| Connection | Connectors may only be inserted when there is no load/the power is switched off. Contact release by means of CK2,5-EWZ (Order No. 1662722) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 125 °C (including heating up of contacts) |
|---|
Material data
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | Copper alloy |
| Contact surface material | Ag (alternatively Au) |
| Contact carrier material | PC |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Electrical characteristics
| Rated voltage (III/3) | 500 V |
|---|---|
| Rated surge voltage | 6 kV |
| Rated current | 16 A |