View larger
Images are for illustrative purposes only. Please refer to data sheet for details
HC-BB46-I-CT-M 47-92 1406546 PHOENIX CONTACT HEAVYCON plug insert, series: BB46, pos. marking: 47 ... 92, 46..
HC-BB46-I-CT-M 47-92
1406546
PHOENIX CONTACT
1 Pcs.
HEAVYCON plug insert, series: BB46, pos. marking: 47 ... 92, 46-pos., crimp connection, with plastic coding profile, can be coded
Contact insert, number of poles: 46+PE, size: B24, Male, Crimped connection, 500 V, 16 A, 0.5 mm² ... 4 mm², Application: Power
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact HC-BB46-I-CT-M heavy-duty plug insert offers a high-density contact arrangement for multi-wire signal and power distribution within protective industrial enclosures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connection method: Crimp connection
- Pollution degree: 3
- Overvoltage category: III
- Number of positions: 46+PE
- Insertion/withdrawal cycles: ≥ 500
- Type: B24
- Connection in acc. with standard: IEC / EN
- Conductor cross section: 0.5 mm² ... 4 mm²
- Connection cross section AWG: 20 ... 12
- Stripping length of the individual wire: 7.5 mm
- Assembly instructions: - Housing heights of h ≥ 72 mm are recommended when there is a high number of wires.
- Ambient temperature (operation): -40 °C ... 125 °C (including heating up of contacts)
- Flammability rating according to UL 94: V0
- Contact material: Copper alloy
- Contact surface material: Ag (alternatively Au)
- Contact carrier material: PC
More info
▲General
| Connection method | Crimp connection |
|---|---|
| Pollution degree | 3 |
| Overvoltage category | III |
| Number of positions | 46+PE |
| Insertion/withdrawal cycles | ≥ 500 |
| Type | B24 |
| Connection in acc. with standard | IEC / EN |
| Conductor cross section | 0.5 mm² ... 4 mm² |
| Connection cross section AWG | 20 ... 12 |
| Stripping length of the individual wire | 7.5 mm |
| Assembly instructions | - Housing heights of h ≥ 72 mm are recommended when there is a high number of wires. |
| Connection | Connectors may only be inserted when there is no load/the power is switched off. Contact release by means of CK2,5-EWZ (Order No. 1662722) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 125 °C (including heating up of contacts) |
|---|
Material data
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | Copper alloy |
| Contact surface material | Ag (alternatively Au) |
| Contact carrier material | PC |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Electrical characteristics
| Rated voltage (III/3) | 500 V |
|---|---|
| Rated surge voltage | 6 kV |
| Rated current | 16 A |