HEAVYCON plug insert, Q5 series, 5-pos., crimp connection Contact insert, number of poles: 5+PE, size: D7, number of connections per pole: 1, Male, Crimped connection, 230 V/400 V, 20 A, 0.5 mm² ... 2.5 mm², Application: Power

Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact HEAVYCON plug insert (part number HC-Q05-I-CT-M) functions as a rugged male connector block built for compact industrial plug and socket assemblies. It secures multiple electrical circuits within rugged housings to ensure dependable power transmission in factory automation and machinery environments.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • General: Connectors may be operated only when there is no load/voltage.
  • Assembly note: To ensure correct use, installation in housing with IP54 protection or better is required
  • Product type: Contact insert with a fixed no. of positions
  • Series: HC-Q
  • Application: Power
  • Type: D7
  • Number of positions: 5
  • Connection profile: 5+PE
  • Contact numbering: 1 - 5
  • Number of connections per position: 1
  • Contact material type: turned
  • Data management status Article revision: 06
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Width: 21 mm
  • Height: 39.5 mm

More info

▲
Technical data

Notes
Generalfor HC-D7 housing, CK2,5-ED crimp contacts (crimp contacts not included in scope of supply)
GeneralConnectors may be operated only when there is no load/voltage.

Mounting
Assembly noteTo ensure correct use, installation in housing with IP54 protection or better is required

Product properties
Product typeContact insert with a fixed no. of positions
SeriesHC-Q
ApplicationPower
TypeD7
Number of positions5
Connection profile5+PE
Contact numbering1 - 5
Number of connections per position1
Contact material typeturned
Data management status
Article revision06
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Dimensions
Dimensional drawing
Width21 mm
Height39.5 mm
Length21 mm
Mechanical characteristics
Contact diameter2.5 mm

Connection data
Connection technology
Connection technologyCrimp connection
Number of connections per position1
Connection in acc. with standardIEC / EN
Conductor connection
Conductor cross section0.5 mm² ... 2.5 mm² (The cross section specification refers to the geometric cross section of the cable used)
Connection cross section AWG20 ... 14
Connection cross section PE contact0.5 mm² ... 2.5 mm²
Connection cross section PE contact AWG20 ... 14
Tightening torque0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Stripping length of the individual wire7.5 mm

Electrical properties
Rated voltage (III/3)230 V (Conductor-PE)
400 V (Conductor-Conductor)
Rated voltage for power contacts230/400 V
Rated surge voltage4 kV
Rated current20 A (power contacts)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 500

Material specifications
Flammability rating according to UL 94V0
Seal materialNBR, conductive
Contact materialCopper alloy
Contact surface materialAg (alternatively Au)
Contact carrier materialPC
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-40 °C ... 125 °C (including heating up of contacts)

Standards and regulations
Testing
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)