PHOENIX CONTACT HC-DD42-I-CT-M HC-DD42-I-CT-M 1584059 PHOENIX CONTACT Contact insert View larger
Images are for illustrative purposes only. Please refer to data sheet for details

HC-DD42-I-CT-M 1584059 PHOENIX CONTACT Contact insert

HC-DD42-I-CT-M

1584059

PHOENIX CONTACT

1 Pcs.

Contact insert Contact insert, number of poles: 42+PE, size: B10, number of connections per pole: 1, Male, Crimped connection, 250 V, 10 A, 0.14 mm² ... 2.5 mm², application: Signal

Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Providing ultra-high-density signal routing, this Phoenix Contact HC-DD42-I-CT-M contact insert packs numerous connection points into a standard B10 housing profile. High-density connector inserts allow complex automation networks and multi-sensor systems to interconnect efficiently within compact machine footprints.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • General: For housing HC-B10
  • General: Connectors may be operated only when there is no load/voltage.
  • Assembly note: To ensure correct use, installation in housing with IP54 protection or better is required
  • Product type: Contact insert with a fixed no. of positions
  • Series: HC-DD
  • Application: Signal
  • Type: B10
  • Number of positions: 42
  • Connection profile: 42+PE
  • Contact numbering: 1 - 42
  • Number of connections per position: 1
  • Contact material type: turned
  • Data management status Article revision: 13
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Width: 34 mm

More info

▲
Technical data

Notes
GeneralFor housing HC-B10
GeneralConnectors may be operated only when there is no load/voltage.
GeneralIt is imperative that guide pins (HC-CST) and sockets (HC-CBU) are used to prevent tip collision due to misalignment.

Mounting
Assembly noteTo ensure correct use, installation in housing with IP54 protection or better is required

Product properties
Product typeContact insert with a fixed no. of positions
SeriesHC-DD
ApplicationSignal
TypeB10
Number of positions42
Connection profile42+PE
Contact numbering1 - 42
Number of connections per position1
Contact material typeturned
rolled
Data management status
Article revision13
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Dimensions
Dimensional drawing
Width34 mm
Height32.5 mm
Length64 mm
Drill hole distance, horizontal57 mm
Drill hole distance, vertical27 mm
Mechanical characteristics
Minimum housing height72 mm
Contact diameter1.6 mm

Connection data
Connection technology
Connection technologyCrimp connection
Number of connections per position1
Connection in acc. with standardIEC / EN
Conductor connection
Conductor cross section0.14 mm² ... 2.5 mm²
Connection cross section AWG26 ... 14
Tightening torque0.8 Nm ... 1.2 Nm (PE connection)
0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Stripping length of the individual wire8 mm (0.14 mm² ... 1.5 mm²)
6 mm (2.5 mm²)

Electrical properties
Rated voltage (III/3)250 V
Rated surge voltage4 kV
Rated current10 A
SCCR5 kA (UL 2237)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 500

Material specifications
Flammability rating according to UL 94V0
Contact materialCopper alloy
Contact surface materialAg (alternatively Au)
Contact carrier materialPC
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-40 °C ... 125 °C (including heating up of contacts)

Standards and regulations
Constructional and testing regulationsDIN VDE 0627/86
DIN VDE 0110/02.79
DIN VDE 0110-1/04.97
IEC 60664-1, DIN IEC 60512
IEC 60352
TestsDIN VDE 0627/86
DIN VDE 0110/02.79
DIN VDE 0110-1/04.97
IEC 60664-1, DIN IEC 60512
IEC 60352
Testing
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.