View larger
HC-D 40-I-CT-M 1584415 PHOENIX CONTACT Contact insert
HC-D 40-I-CT-M
1584415
PHOENIX CONTACT
1 Pcs.
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact HC-D 40-I-CT-M is a contact insert engineered to provide high-density signal and data connections inside protective heavy-duty industrial housings. These inserts allow technicians to group large numbers of conductors into secure, pluggable interfaces for automated production lines. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- General: Connectors may be operated only when there is no load/voltage.
- General: This product replaces 1679485 HC-D 40-ESTC-R
- Assembly note: To ensure correct use, installation in housing with IP54 protection or better is required
- Product type: Contact insert with a fixed no. of positions
- Series: HC-D
- Application: Signal
- Type: B16
- Number of positions: 40
- Note number of positions: 40+PE
- Connection profile: 40+PE
- Number of connections per position: 1
- Contact material type: turned
- Data management status Article revision: 11
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Width: 34 mm
More info
▲| General | For HEAVYCON ADVANCE and HEAVYCON housing of type B16, crimp contacts: CK 1,6-ED... (not included in scope of supply) |
| General | Connectors may be operated only when there is no load/voltage. |
| General | It is imperative that guide pins (HC-CST) and sockets (HC-CBU) are used to prevent tip collision due to misalignment. |
| General | This product replaces 1679485 HC-D 40-ESTC-R |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| Product type | Contact insert with a fixed no. of positions |
| Series | HC-D |
| Application | Signal |
| Type | B16 |
| B32 | |
| Number of positions | 40 |
| Note number of positions | 40+PE |
| Connection profile | 40+PE |
| Number of connections per position | 1 |
| Contact material type | turned |
| rolled | |
| Data management status | |
| Article revision | 11 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Width | 34 mm |
| Height | 32.8 mm |
| Length | 83.5 mm |
| Drill hole distance, horizontal | 77.5 mm |
| Mechanical characteristics | |
| Contact diameter | 1.6 mm |
| Connection technology | |
| Connection technology | Crimp connection |
| Number of connections per position | 1 |
| Connection in acc. with standard | IEC / EN |
| Conductor connection | |
| Conductor cross section | 0.14 mm² ... 2.5 mm² |
| Connection cross section AWG | 26 ... 14 |
| Tightening torque | 0.8 Nm ... 1.2 Nm (PE connection) |
| 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) | |
| Stripping length of the individual wire | 8 mm (0.14 mm² ... 1.5 mm²) |
| 6 mm (2.5 mm²) | |
| Rated voltage (III/3) | 250 V |
| Rated surge voltage | 4 kV |
| Rated current | 10 A |
| SCCR | 5 kA (UL 2237) |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 500 |
| Flammability rating according to UL 94 | V0 |
| Contact material | Copper alloy |
| Contact surface material | Ag (alternatively Au) |
| Contact carrier material | PC |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 125 °C (including heating up of contacts) |
| Constructional and testing regulations | DIN VDE 0627/86 |
| DIN VDE 0110/02.79 | |
| DIN VDE 0110-1/04.97 | |
| IEC 60664-1, DIN IEC 60512 | |
| IEC 60352 | |
| Tests | DIN VDE 0627/86 |
| DIN VDE 0110/02.79 | |
| DIN VDE 0110-1/04.97 | |
| IEC 60664-1, DIN IEC 60512 | |
| IEC 60352 | |
| Testing | |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |