PHOENIX CONTACT HC-A10-I-UT-M HC-A10-I-UT-M 1585294 PHOENIX CONTACT Contact insert View larger
Images are for illustrative purposes only. Please refer to data sheet for details

HC-A10-I-UT-M 1585294 PHOENIX CONTACT Contact insert

HC-A10-I-UT-M

1585294

PHOENIX CONTACT

1 Pcs.

Contact insert Contact insert, number of poles: 10+PE, size: D15, number of connections per pole: 1, Male, Screw connection, 250 V, 16 A, 0.5 mm² ... 2.5 mm² Contact insert, number of positions: 10+PE, size: D15, number of connections per position: 1, Pin, Screw connection, 250 V, 16 A, 0.5 mm2 ... 2.5 mm2

Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact HC-A10-I-UT-M is a contact insert used within rectangular heavy-duty connector assemblies to join multiple control or power circuits securely. They offer a modular, insulated platform that simplifies wiring maintenance and system expansion in industrial environments.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • General: for flexible conductors with or without ferrules
  • General: Connectors may be operated only when there is no load/voltage.
  • General: for housing HC-D15
  • Assembly note: To ensure correct use, installation in housing with IP54 protection or better is required
  • Product type: Contact insert with a fixed no. of positions
  • Series: HC-A
  • Type: D15
  • Number of positions: 10
  • Connection profile: 10+PE
  • Contact numbering: 1 - 10
  • Number of connections per position: 1
  • Contact material type: turned
  • Screwdriver blade: 0.5 x 3.5 mm
  • Data management status Article revision: 06
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3

More info

▲
Technical data

Notes
Generalfor flexible conductors with or without ferrules
GeneralConnectors may be operated only when there is no load/voltage.
Generalfor housing HC-D15

Mounting
Assembly noteTo ensure correct use, installation in housing with IP54 protection or better is required
for plastic coding profiles: 4 pcs.

Product properties
Product typeContact insert with a fixed no. of positions
SeriesHC-A
TypeD15
Number of positions10
Connection profile10+PE
Contact numbering1 - 10
Number of connections per position1
Contact material typeturned
Screwdriver blade0.5 x 3.5 mm
Data management status
Article revision06
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Dimensions
Dimensional drawing
Width23 mm
Height34.1 mm
Length55.5 mm
Drill hole distance, horizontal49.5 mm
Drill hole distance, vertical16 mm
Mechanical characteristics
Contact diameter2.5 mm

Connection data
Connection technology
Connection technologyScrew connection
Number of connections per position1
Connection in acc. with standardIEC / EN
Conductor connection
Conductor cross section0.5 mm² ... 2.5 mm²
Connection cross section AWG20 ... 14
Tightening torque0.7 Nm ... 1 Nm (PE connection)
0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
0.5 Nm
Stripping length of the individual wire7 mm

Electrical properties
Rated voltage (III/3)250 V
Rated surge voltage4 kV
Rated current16 A
SCCR5 kA (UL 2237)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 500

Material specifications
Flammability rating according to UL 94V0
Contact materialCopper alloy
Contact surface materialAg
Contact carrier materialPC
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-40 °C ... 125 °C (including heating up of contacts)

Standards and regulations
Testing
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.