Phoenix Contact HC-D 7-I-CT-F heavy-duty female insert is engineered for compact connector housings, delivering dependable signal transmission in restricted spaces. These modular blocks support secure internal wiring for factory equipment and industrial machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of power contacts (EF012216): 7
- Number of control contacts (EF012217): 0
- Contact insert without contacts (EF007324): Yes
- Contact type (EF001587): Bus
- Number of poles (EF001391): 7
- Diameter plug-in contact (EF007320): 1.6 mm
- Material connector insert (EF007545): Thermoplastic
- Rated current In (EF008250): 10 A
- Ambient temperature (EF002386): 125 °C
- Operating temperature (EF002393): -40 °C
- Rated voltage (EF000228): 250 V
- Rated surge voltage (EF002993): 4 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 3
- Type of electric connection (EF003961): Crimp connection
- With wire protection (EF000550): No
More info
▲General
| Note | For HC-D7 housing, crimp contacts CK1,6-ED (crimp contacts not included in scope of supply) |
|---|---|
| Connection method | Crimp connection |
| Pollution degree | 3 |
| Overvoltage category | III |
| Constructional and testing regulations | DIN VDE 0627/86 |
| DIN VDE 0110/02.79 | |
| DIN VDE 0110-1/04.97 | |
| IEC 60664-1, DIN IEC 60512 | |
| IEC 60352 | |
| Number of positions | 7+PE |
| Insertion/withdrawal cycles | ≥ 500 |
| Type | D7 |
| Connection in acc. with standard | IEC / EN |
| Conductor cross section | 0.14 mm² ... 2.5 mm² |
| Connection cross section AWG | 26 ... 14 |
| Stripping length of the individual wire | 8 mm (0.14 - 1.5 mm²) |
| 6 mm (2.5 mm²) | |
| Assembly instructions | Connectors may be operated only when there is no load/voltage. |
| Connection | The inserts may only be used in plastic housing at voltages > 42 V, as it is not possible to establish a connection between the protective conductor and housing. Product already includes one IP65 sealing screw. |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 125 °C (including heating up of contacts) |
|---|
Material data
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | Copper alloy |
| Contact surface material | Ag (alternatively Au) |
| Contact carrier material | PC |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Electrical characteristics
| Rated voltage (III/3) | 250 V |
|---|---|
| Rated surge voltage | 4 kV |
| Rated current | 10 A |