HC-B 16-EBUQ-2,5 1605572 PHOENIX CONTACT Contact insert
HC-B 16-EBUQ-2,5
1605572
PHOENIX CONTACT
10 Pcs.
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact model HC-B 16-EBUQ-2,5 1605572 is a contact insert engineered for secure power and signal transmission in heavy-duty connector housings. Industrial inserts provide dependable plug-and-socket interfaces for machinery control panels and electrical distribution.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- General: Connectors may be operated only when there is no load/voltage.: General: Connectors may be operated only when there is no load/voltage.
- Assembly note: To ensure correct use, installation in housing with IP54 protection or better is required: Assembly note: To ensure correct use, installation in housing with IP54 protection or better is required
- Product type: Contact insert with a fixed no. of positions
- Series: HC-B
- Type: B16
- Number of positions: 16
- Connection profile: 16+PE
- Contact numbering: 1 - 16
- Number of connections per position: 1
- Contact material type: rolled
- Data management status Article revision: 06
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Width: 34 mm
- Height: 37 mm
- Length: 84.5 mm
More info
▲| General | Connectors may be operated only when there is no load/voltage. |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| Product type | Contact insert with a fixed no. of positions |
| Series | HC-B |
| Type | B16 |
| B32 | |
| Number of positions | 16 |
| Connection profile | 16+PE |
| Contact numbering | 1 - 16 |
| Number of connections per position | 1 |
| Contact material type | rolled |
| Data management status | |
| Article revision | 06 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Width | 34 mm |
| Height | 37 mm |
| Length | 84.5 mm |
| Drill hole distance, horizontal | 77.5 mm |
| Drill hole distance, vertical | 27 mm |
| Mechanical characteristics | |
| Contact diameter | 2.5 mm |
| Connection technology | |
| Connection technology | QUICKON connection |
| Number of connections per position | 1 |
| Conductor connection | |
| Conductor cross section | 0.34 mm² ... 2.5 mm² (Litz wire structure VDE 0295, Class 1 - 5/litz wire diameter >= 0.2 mm) |
| Connection cross section AWG | 22 ... 14 |
| Tightening torque | 0.8 Nm ... 1.2 Nm (PE connection) |
| 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) | |
| Rated voltage (III/3) | 500 V |
| 500 V | |
| Rated surge voltage | 6 kV |
| 6 kV | |
| Rated current | 16 A |
| 16 A |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 500 |
| Material Wire insulation | PVC / PE |
| Flammability rating according to UL 94 | V0 |
| Contact material | Copper alloy |
| Contact surface material | Ag |
| Contact carrier material | PA |
| Standards/regulations | PA: Fire protection in rail vehicles - requirement sets R22 and R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL2) |
| PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 125 °C (including heating up of contacts) |
| Ambient temperature (assembly) | -25 °C ... 50 °C |
| Testing | |
| Standards/regulations | PA: Fire protection in rail vehicles - requirement sets R22 and R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL2) |
| PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) | |