The Phoenix Contact HDFKV 25-TWIN-DP panel feed-through terminal block establishes dependable multi-conductor pathways through structural enclosure panels. Panel feed-through systems are widely integrated into electrical distribution boards to streamline complex wiring between external systems and internal equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 0709631
- Packing unit: 25 pc
- Note: Made to Order (non-returnable)
- GTIN: 4017918117078
- Weight per Piece (excluding packing): 91.660 g
- Custom tariff number: 85369010
- Country of origin: DE (Germany)
- Number of levels: 1
- Number of connections: 2
- Nominal cross section: 25 mm²
- Color: gray
- Insulating material: PA
- Flammability rating according to UL 94: V2
- Rated surge voltage: 6 kV
- Degree of pollution: 3
- Overvoltage category: III
More info
▲Key Commercial Data
| Orderkey | 0709631 |
|---|---|
| Packing unit | 25 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4017918117078 |
| Weight per Piece (excluding packing) | 91.660 g |
| Custom tariff number | 85369010 |
| Country of origin | DE (Germany) |
General
| Number of levels | 1 |
|---|---|
| Number of connections | 2 |
| Nominal cross section | 25 mm² |
| Color | gray |
| Insulating material | PA |
| Flammability rating according to UL 94 | V2 |
| Rated surge voltage | 6 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Connection in acc. with standard | IEC 60947-7-1 |
| Nominal current IN | 101 A (the maximum load current must not be exceeded by the total current of the connected conductors) |
| Maximum load current | 125 A |
| Nominal voltage UN | 500 V |
| Open side panel | No |
| Number of positions | 1 |
Connection data
| Note | Terminal sleeve |
|---|---|
| Connection side | Level 1 ext. 1 |
| Connection method | Screw connection |
| Conductor cross section solid min. | 6 mm² |
| Conductor cross section solid max. | 35 mm² |
| Conductor cross section flexible min. | 10 mm² |
| Conductor cross section flexible max. | 25 mm² |
| Conductor cross section AWG min. | 10 |
| Conductor cross section AWG max. | 2 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 4 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 25 mm² |
| 2 conductors with same cross section, solid min. | 2.5 mm² |
| 2 conductors with same cross section, solid max. | 10 mm² |
| 2 conductors with same cross section, stranded min. | 4 mm² |
| 2 conductors with same cross section, stranded max. | 10 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. | 2.5 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. | 10 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 2.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 10 mm² |
| Stripping length | 19 mm |
| Internal cylindrical gage | B8 |
| Screw thread | M5 |
| Tightening torque, min | 4 Nm |
| Tightening torque max | 4.5 Nm |
| Connection side | Level 1 int. 1 |
| Connection method | Screw connection |
| Conductor cross section solid min. | 6 mm² |
| Conductor cross section solid max. | 35 mm² |
| Conductor cross section flexible min. | 10 mm² |
| Conductor cross section flexible max. | 25 mm² |
| Conductor cross section AWG min. | 10 |
| Conductor cross section AWG max. | 2 |
| Internal cylindrical gage | B8 |
Standards and Regulations
| Connection in acc. with standard | CSA |
|---|---|
| IEC 60947-7-1 | |
| IEC / EN | |
| Flammability rating according to UL 94 | V2 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |