View larger
HCC 4-CLT-NS35 SET 1279180 PHOENIX CONTACT Surge Protection Base Element, For CLIXTRAB Surge Protection, Sui..
HCC 4-CLT-NS35 SET
1279180
PHOENIX CONTACT
50 Pcs.
Automation > Installation clamp for meters
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact HCC 4-CLT-NS35 SET surge protection base element provides a stable mounting and connection foundation for CLIXTRAB surge protection devices. Base elements of this style secure protective modules to standard DIN rails while routing system currents safely.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General notes: for surge protection CLIXTRAB suitable for the HCC 4 series
- Product Type: Feed-through clamp
- No. of poles: 10
- Number of connections: 10
- Insulation characteristics Overvoltage Category: Iii
- Degree of pollution: 2
- Sizing Impulse Voltage: 4 kV
- Number of connections per plan: 10
- Standard-compliant connection: IEC 61984
- Nominal voltage: 400 V
- width: 72.6 mm
- height: 75.9 mm
- Depth: 35.3 mm
- Color: grey
- Combustibility class according to UL 94: V0
- Insulation Material Group: The
More info
▲| General notes | for surge protection CLIXTRAB suitable for the HCC 4 series |
| General notes | |
| note | The use of surge protection plugs reduces the load current of the terminal block (see technical data for CLT surge protection plugs). |
| Product Type | Feed-through clamp |
| No. of poles | 10 |
| Number of connections | 10 |
| Insulation characteristics | |
| Overvoltage Category | Iii |
| Degree of pollution | 2 |
| Sizing Impulse Voltage | 4 kV |
| Number of connections per plan | 10 |
| Standard-compliant connection | IEC 61984 |
| Nominal voltage | 400 V |
| width | 72.6 mm |
| height | 75.9 mm |
| Depth | 35.3 mm |
| Color | grey |
| Combustibility class according to UL 94 | V0 |
| Insulation Material Group | The |
| Insulation material | PA |
| Cold static insulation material insert | -60 °C |
| Insulation Material Relative Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface Flammability NFPA 130 (ASTM E 162) | Exceeded |
| NFPA 130 (ASTM E 662) Specific Optical Density of Fumes | Exceeded |
| NFPA 130 Fume Toxicity (SMP 800C) | Exceeded |
| Broadband vibration/noise | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Spectrum | Electrical Life Check Category 1, Class B, Body Mounted |
| Frequency | f1= 5 Hz a f2= 150 Hz |
| ASD Level | 0.964 (m/s²)²/Hz |
| Acceleration | 0.58g |
| Test duration per axle | 5 h |
| Test Directions | X, Y, and Z axis |
| Result | Test passed |
| Shock | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Shock Form | Semi-sinusoidal |
| Acceleration | 5g |
| Shock Duration | 30 ms |
| Number of shocks per direction | 3 |
| Test Directions | X, Y and Z axis (pos. and neg.) |
| Result | Test passed |
| Environmental conditions | |
| Ambient temperature (operating) | -60 °C (for maximum operating temperature see derating curve) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for short duration, no longer than 24 h, -60 °C °C to +70 °C) |
| Ambient temperature (mounting) | -5 °C ... 70 °C |
| Ambient Temperature (Activation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Standard-compliant connection | IEC 61984 |
| Mounting type | NS 35/7.5 |
| NS 35/15 |