View larger
HC-M-04-CT-M 1414362 PHOENIX CONTACT Module inserts contacts, Number of poles: 4, Type of contact: Male, Tec..
HC-M-04-CT-M
1414362
PHOENIX CONTACT
5 Pcs.
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact HC-M-04-CT-M module inserts contacts provide flexible modular integration for power transmission lines inside heavy-duty connector setups. Multi-pole modular blocks like this enable custom electrical configurations within industrial machinery enclosures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General: Connectors may be operated only when there is no load/voltage.
- Assembly note: To ensure correct use, installation in housing with IP54 protection or better is required
- Product type: Modular contact insert
- Series: HC-M-04
- Application: Power
- Number of positions: 4
- Connection profile: 4
- Contact numbering: 1 - 4
- Number of module slots: 1
- No. of power contacts: 4
- No. of control contacts: 0
- Contact material type: turned
- Data management status Article revision: 02
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Connection technology Connection technology: Crimp connection
More info
▲| General | For HEAVYCON HC-B6 to B48 housing, HC-M-B...-MF-... module carrier frame required, crimp connection, crimp contacts not supplied as standard. |
| General | Connectors may be operated only when there is no load/voltage. |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| The module cannot be used simultaneously with the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers. |
| Product type | Modular contact insert |
| Series | HC-M-04 |
| Application | Power |
| Number of positions | 4 |
| Connection profile | 4 |
| Contact numbering | 1 - 4 |
| Number of module slots | 1 |
| No. of power contacts | 4 |
| No. of control contacts | 0 |
| Contact material type | turned |
| Data management status | |
| Article revision | 02 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Connection technology | |
| Connection technology | Crimp connection |
| Connection in acc. with standard | IEC / EN |
| Conductor connection | |
| Conductor cross section | 1.5 mm² ... 6 mm² |
| Connection cross section AWG | 16 ... 10 |
| Stripping length of the individual wire | 9 mm (9.6 mm (4-6 mm²)) |
| 14 mm (4 ... 6 mm²) | |
| Dimensional drawing | |
| Width | 34.2 mm |
| Height | 44.6 mm |
| Length | 14.6 mm |
| Mechanical characteristics | |
| Minimum housing height | 52 mm |
| Contact diameter | 4 mm |
| Rated voltage (III/2) contacts | 1000 V |
| Rated voltage (III/3) | 690 V |
| Rated surge voltage (III/2) | 8 kV |
| Rated surge voltage (III/3) | 6 kV |
| Rated surge voltage | 6 kV |
| Rated current | 40 A |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 500 |
| Flammability rating according to UL 94 | V0 |
| Contact material | Copper alloy |
| Contact surface material | Ag |
| Contact carrier material | PC |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 125 °C |
| Testing | |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |