PHOENIX CONTACT PTI 16/S BU PTI 16/S BU 3214023 PHOENIX CONTACT Installation terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PTI 16/S BU 3214023 PHOENIX CONTACT Installation terminal block

PTI 16/S BU

3214023

PHOENIX CONTACT

50 Pcs.

Installation terminal block Terminal block, nominal voltage: 500 V, nominal current: 76 A, Push-in connection, 1st floor, Dimensioning cross-section: 16 mm², cross-section: 0.5 mm² - 16 mm², installation class: NS 35/7.5, NS 35/15, colour: blue

Automation > Multi level installation terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

PTI 16/S BU is an installation terminal block utilized for color-coded neutral or phase conductor routing inside electrical panels. Terminal blocks provide reliable mechanical clamping and high-current distribution across complex commercial and industrial power setups. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Connectable conductor cross section solid-core (EF007337): 0.5 mm²
  • Connectable conductor cross section multi-wired (EF007343): 0.5 mm²
  • Rated current In (EF008250): 76 A
  • Rated voltage (EF000228): 500 V
  • Width (EF000008): 10.15 mm
  • Height (EF000040): 77.65 mm
  • Depth (EF000049): 49.6 mm
  • Closing plate required (EF002525): Yes
  • Basic colour (EF002671): Blue
  • PE-function (EF002672): No

More info

▲

Key Commercial Data

Orderkey3214023
Packing unit50 pc
Minimum order quantity50 pc
Catalog pagePage 118 (C-1-2017)
GTIN4046356702225
Weight per Piece (excluding packing)28.000 g
Custom tariff number85369010
Country of originPL (Poland)

General

Number of levels1
Number of connections2
Potentials1
Nominal cross section16 mm²
Colorblue
Insulating materialPA
Flammability rating according to UL 94V0
Rated surge voltage6 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition2.43 W
Maximum load current76 A (with 16 mm² conductor cross section)
Nominal current IN76 A
Nominal voltage UN500 V
Open side panelYes
Shock protection test specificationDIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protectionguaranteed
Finger protectionguaranteed
Result of surge voltage testTest passed
Surge voltage test setpoint7.3 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint1.89 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed
Result of bending testTest passed
Bending test rotation speed10 rpm
Bending test turns135
Bending test conductor cross section/weight0.5 mm² / 0.3 kg
16 mm² / 2.9 kg
Tensile test resultTest passed
Conductor cross section tensile test0.5 mm²
Tractive force setpoint20 N
Conductor cross section tensile test16 mm²
Tractive force setpoint100 N
Result of tight fit on supportTest passed
Tight fit on carrierNS 35
Setpoint5 N
Result of voltage-drop testTest passed
Requirements, voltage drop≤ 3.2 mV
Result of temperature-rise testTest passed
Short circuit stability resultTest passed
Conductor cross section short circuit testing16 mm²
Short-time current1.92 kA
Result of thermal testTest passed
Ageing test for screwless modular terminal block temperature cycles192
Proof of thermal characteristics (needle flame) effective duration30 s
Result of aging testTest passed
Oscillation, broadband noise test resultTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2008-03
Test spectrumService life test category 2, bogie-mounted
Test frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s2)2/Hz
Acceleration3.12 g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
Shock test resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2008-03
Shock formHalf-sine
Acceleration30g
Shock duration18 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width10.2 mm
End cover width2.2 mm
Length77.7 mm
Height49.6 mm
Height NS 35/7,551.1 mm
Height NS 35/1558.6 mm

Connection data

Connection methodPush-in connection
Stripping length18 mm
Connection in acc. with standardIEC 60947-7-1
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.4
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible4
Conductor cross section flexible, with ferrule without plastic sleeve min.0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.16 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.16 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.4 mm²
Internal cylindrical gageA6

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.