View larger
GDT-US-NG/80-P 2910332 PHOENIX CONTACT Type 1/2 surge protection plug
GDT-US-NG/80-P
2910332
PHOENIX CONTACT
1 Pcs.
Automation > Accessories/spare parts for surge protection power supply systems
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for electrical systems following North American design practices, the Phoenix Contact GDT-US-NG/80-P (2910332) operates as a Type 1/2 surge protection plug. Industrial installations integrate these gas discharge tube plugs into main distribution panels to manage severe lightning surges and neutral-to-ground paths. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2910332
- Packing unit: 1 pc
- Note: Made to Order (non-returnable)
- GTIN: 4055626445328
- Weight per Piece (excluding packing): 36.000 g
- Custom tariff number: 85363030
- Country of origin: US (United States)
- Height: 47 mm
- Width: 17.7 mm
- Depth: 67.3 mm
- Horizontal pitch: 1 Div.
- Degree of protection: IP20
- Ambient temperature (operation): -40 °C ... 80 °C
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Permissible humidity (operation): 5 % ... 95 %
More info
▲Key Commercial Data
| Orderkey | 2910332 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626445328 |
| Weight per Piece (excluding packing) | 36.000 g |
| Custom tariff number | 85363030 |
| Country of origin | US (United States) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
General
| IEC test classification | II |
|---|---|
| T2 | |
| EN type | T2 |
| Mode of protection | N-PE |
| Mounting type | on base element |
| Color | jet black RAL 9005 |
| Housing material | PA 6.6 |
| PBT | |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | Male |
| Number of positions | 1 |
| Surge protection fault message | optical |
Protective circuit
| Nominal voltage UN | 240/415 V AC (TN-S) |
|---|---|
| 240/415 V AC (TT) | |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 264 V AC |
| Residual current IPE | ≤ 5 µA |
| Standby power consumption PC | ≤ 1.3 mVA |
| Nominal discharge current In(8/20) µs | 50 kA |
| Maximum discharge current Imax(8/20) µs | 50 kA |
| Follow current interrupt rating Ifi | 100 A (260 V) |
| Voltage protection level Up | ≤ 1.7 kV |
| Residual voltage Ures | ≤ 0.6 kV (at In) |
| ≤ 0.5 kV (at 10 kA) | |
| ≤ 0.5 kV (at 5 kA) | |
| ≤ 0.4 kV (at 3 kA) | |
| Front of wave sparkover voltage at 6 kV (1.2/50) µs | ≤ 1.7 kV |
| TOV behavior at UT | 1200 V AC (200 ms / withstand mode) |
| Response time tA | ≤ 100 ns |
UL specifications
| SPD Type | 1CA |
|---|---|
| Maximum continuous operating voltage MCOV | 264 V AC |
| Nom. voltage | 240 V AC |
| Mode of protection | N-G |
| Power distribution system | Single phase |
| Nominal frequency | 50/60 Hz |
| Voltage protection rating VPR | 1200 V |
| Nominal discharge current In | 20 kA |
| Maximum Surge Current per Phase | 80 kA |