View larger
PT 10,3-HESI 1000V 3062142 PHOENIX CONTACT Fuse modular terminal block
PT 10,3-HESI 1000V
3062142
PHOENIX CONTACT
10 Pcs.
Automation > Fuse terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact PT 10,3-HESI 1000V (model PT 10,3-HESI 1000V 3062142) is a fuse modular terminal block designed for secure circuit protection and wire termination inside electrical distribution enclosures. Such components provide an integrated housing for protective elements, allowing technicians to isolate individual control loops and safeguard sensitive devices from overcurrent events on standard mounting rails. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connectable conductor cross section solid-core (EF007337): 1.5 mm²
- Rated current In (EF008250): 20 A
- Rated voltage (EF000228): 1000 V
- Number of levels (EF002659): 1
- Mounting method (EF000003): DIN rail (top hat rail) 35 mm
- Width (EF000008): 17.5986 mm
- Height (EF000040): 89.12476 mm
- Depth (EF000049): 60.49923 mm
- Closing plate required (EF002525): No
- Colour (EF000007): Black
More info
▲Key Commercial Data
| Orderkey | 3062142 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 10 pc |
| Catalog page | Page 115 (C-1-2017) |
| GTIN | 4046356724746 |
| Weight per Piece (excluding packing) | 53.760 g |
| Custom tariff number | 85369095 |
| Country of origin | CN (China) |
General
| Number of levels | 1 |
|---|---|
| Number of connections | 2 |
| Nominal cross section | 10 mm² |
| Color | black |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Maximum power dissipation for nominal condition | 3 W |
| Fuse | Midget / 10.3 x 38 |
| Rated surge voltage | 6 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | IIIa |
| Maximum power dissipation | 3 W (Fuse insert) |
| Connection in acc. with standard | IEC 60269-1/-2 |
| Maximum load current | 20 A (the current and voltage are determined by the fuse) |
| Nominal current IN | 20 A (the current and voltage are determined by the fuse) |
| Nominal voltage UN | 1000 V (the current and voltage are determined by the fuse) |
| Open side panel | No |
| Shock protection test specification | DIN EN 50274 (VDE 0660-514):2002-11 |
| Back of the hand protection | guaranteed |
| Finger protection | guaranteed |
Connection data
| Conductor cross section solid min. | 1.5 mm² |
|---|---|
| Conductor cross section solid max. | 10 mm² |
| Conductor cross section flexible min. | 1.5 mm² |
| Conductor cross section flexible max. | 10 mm² |
| Conductor cross section AWG min. | 16 |
| Conductor cross section AWG max. | 6 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 10 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 1.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 10 mm² |
| Connection method | Push-in connection |
| Stripping length | 18 mm |
Standards and Regulations
| Connection in acc. with standard | IEC 60269-1/-2 |
|---|---|
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |