View larger
FTP-3/12S 3069952 PHOENIX CONTACT Test plug
FTP-3/12S
3069952
PHOENIX CONTACT
1 Pcs.
Automation > Test plug for terminal blocks
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Functioning as an FTP-3/12S 3069952 PHOENIX CONTACT Test plug, this multi-position component allows engineers to perform comprehensive diagnostic checks on complex metering and protection systems. Test plug terminal blocks integrate smoothly into switchgear assemblies to isolate circuits and monitor signals safely under load. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Test plug terminal block
- Number of positions: 12
- Pitch: 8.2 mm
- Potentials: 12
- Maximum power dissipation for nominal condition: 1.31 W
- Nominal cross section: 6 mm²
- Test socket torque: 0.5
- Note: The conductor cross section depends on the cable lug used
- Conductor cross section flexible: 0.5 mm² ... 2.5 mm²
- Conductor cross section, flexible [AWG]: 20 ... 14 (converted acc. to IEC)
- Nominal current: 20 A
- Maximum load current: 20 A
- Nominal voltage: 400 V AC/DC
- Nominal cross section: 2.5 mm²
- Width: 130.4 mm
- Height: 86 mm
More info
▲| Product type | Test plug terminal block |
| Number of positions | 12 |
| Pitch | 8.2 mm |
| Potentials | 12 |
| Maximum power dissipation for nominal condition | 1.31 W |
| Nominal cross section | 6 mm² |
| Test socket torque | 0.5 |
| Note | The conductor cross section depends on the cable lug used |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 20 ... 14 (converted acc. to IEC) |
| Nominal current | 20 A |
| Maximum load current | 20 A |
| Nominal voltage | 400 V AC/DC |
| Nominal cross section | 2.5 mm² |
| Dimensional drawing | |
| Width | 130.4 mm |
| Height | 86 mm |
| Pitch | 8.2 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient conditions | |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |