View larger
PSR-SCP- 24DC/TS/M 2986012 PHOENIX CONTACT Safety module
PSR-SCP-24DC/TS/M
2986012
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A safety module such as the Phoenix Contact PSR-SCP-24DC/TS/M 2986012 acts as a core logic controller in industrial machine safety chains to monitor emergency stops, light curtains, and protective doors. These devices ensure that mechanical movement is safely halted when a hazard is detected.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2986012
- Packing unit: 1 pc
- Catalog page: Page 293 (C-6-2017)
- GTIN: 4046356346979
- Weight per Piece (excluding packing): 154.000 g
- Custom tariff number: 85371098
- Country of origin: DE (Germany)
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Width: 67.5 mm
- Height: 99 mm
- Depth: 114.5 mm
- Ambient temperature (operation): -20 °C ... 55 °C
- Ambient temperature (storage/transport): -20 °C ... 70 °C
- Max. permissible relative humidity (operation): 75 % (On average, 85 % occasionally)
- Max. permissible humidity (storage/transport): 75 % (On average, 85 % occasionally)
- Air pressure (operation): 70 kPa ... 108 kPa (up to 3000 m above sea level)
More info
▲Key Commercial Data
| Orderkey | 2986012 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 293 (C-6-2017) |
| GTIN | 4046356346979 |
| Weight per Piece (excluding packing) | 154.000 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (On average, 85 % occasionally) |
| Max. permissible humidity (storage/transport) | 75 % (On average, 85 % occasionally) |
| Air pressure (operation) | 70 kPa ... 108 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Maximum altitude | max. 2000 m (See Appendix "Using PSR-TRISAFE modules at altitudes greater than 2000 m above sea level") |
Power supply
| Rated control circuit supply voltage US | 24 V DC (A1/A2) |
|---|---|
| 18 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple) | |
| Rated control supply current IS | typ. 110 mA |
| Limiting continuous current | max. 6 A (For looped-through current paths A1/A1 and A2/A2) |
| Filter time | typ. 20 ms (Load-dependent, in the event of voltage dips at US) |
| Status display | 3x LED green, 1x LED red |
| Protective circuit | Yes, within the scope of the operating voltage limits |
Digital inputs
| Description of the input | Digital, type HTL |
|---|---|
| Number of inputs | 10 (Two-channel, up to SIL 3) |
| 20 (Single-channel, up to SIL 2) | |
| Input voltage range "0" signal | 0 V DC ... 5 V DC (for safe Off) |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Current consumption | typ. 4 mA |
| Cable length | max. 2000 m |
| Status display | 20 x LED green (1 LED per input) |
Digital outputs
| Number of outputs | 4 (Safe semiconductor outputs, up to Cat. 4 in accordance with EN ISO 13849-1) |
|---|---|
| 2 (Ground switching outputs) | |
| Nominal output voltage | 24 V DC (Supply via 24 V/0 V) |
| Nominal output voltage range | 18 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple) |
| Limiting continuous current | 2 A (Per channel, see Derating) |
| 2 A (Total current of all outputs) | |
| Output voltage | < 5 V (Low state) |
| Leakage current | max. 2 mA |
| Max. capacitive load | max. 1 µF (Electronic components) |
| Max. inductive load | See "Protective circuit" |
| Test pulses | < 1 ms |
| Note on protection circuit | Yes, within the scope of the operating voltage limits |
| Short-circuit protection | Yes |
| Status display | 4 x LED green (1 LED per output) |
Clock outputs
| Output description | Digital |
|---|---|
| Number of outputs | 2 |
| Voltage | 24 V DC (Supply via 24 V/0 V) |
| Limiting continuous current | 100 mA |
| Test pulses | < 1 ms |
| Short-circuit protection | Yes |
Alarm outputs
| Output description | Digital |
|---|---|
| Number of outputs | 4 |
| Voltage | 24 V DC (Supply via 24 V/0 V) |
| Limiting continuous current | 100 mA |
| Short-circuit protection | Yes |
General
| Nominal operating mode | 100% operating factor |
|---|---|
| Net weight | 154 g |
| Mounting position | On horizontal DIN rail |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
| Housing material | Polyamide PA non-reinforced |
| Housing color | yellow |
| Number of possible extension modules | 1 (Max. continuous current via PSR-TBUS: 4 A) |
| Number of possible safe extension modules | 10 (Max. continuous current via PSR-TBUS: 4 A) |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Torque | 0.5 Nm ... 0.6 Nm |
| 5 lbf-in. ... 7 lbf-in. |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 2 (1-channel parameterization) |
| 3 (2-channel parameterization) | |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 2 (1-channel parameterization) |
| 3 (2-channel parameterization) | |
| Designation | EN ISO 13849 |
| Performance level (PL) | d (1-channel parameterization) |
| e (2-channel parameterization) | |
| Category | 2 (1-channel parameterization) |
| 4 (2-channel parameterization) | |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 2 (1-channel parameterization) |
| 3 (2-channel parameterization) | |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | max. 3 (Reference IEC 61508) |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Vibration (operation) | 2g |
| Shock (operation) | 10g (Δt = 11 ms, three shocks in each space direction) |
| 10g (Δt = 16 ms, continuous shock, 1000 shocks in each space direction) |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |