View larger
SAC-4P-10,0-600/M 8FR VA 1014628 PHOENIX CONTACT Sensor/actuator cable
SAC-4P-10,0-600/M 8FR VA
1014628
PHOENIX CONTACT
50 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A sensor/actuator cable like the Phoenix Contact SAC-4P-10,0-600/M 8FR VA connects field instrumentation to I/O blocks within automated machinery and industrial processing lines, providing dependable signal continuity. Cordsets of this type are essential for decentralized architectures.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Sensor/actuator cable
- Number of positions: 4
- Nominal voltage U N: 48 V AC
- Connection 1 Type: free cable end
- Connection 2 Type: Socket angled M8
- Number of positions: 4
- Cable length: 10 m
- Cable weight: 23 kg/km
- Number of positions: 4
- Shielded: no
- Cable type: Halogen-free PP gray [600]
- Conductor structure signal line: 32x 0.10 mm
- AWG signal line: 24
- Conductor cross section: 4x 0.25 mm² (Signal line)
- Wire diameter incl. insulation: 1.17 mm ±0.02 mm (Signal line)
- External cable diameter: 4.50 mm ±0.15 mm
More info
▲| Product type | Sensor/actuator cable |
| Number of positions | 4 |
| Nominal voltage UN | 48 V AC |
| 60 V DC |
| Connection 1 | |
| Type | free cable end |
| Connection 2 | |
| Type | Socket angled M8 |
| Number of positions | 4 |
| Cable length | 10 m |
| Halogen-free PP gray [600] | |
| Dimensional drawing | |
| Cable weight | 23 kg/km |
| Number of positions | 4 |
| Shielded | no |
| Cable type | Halogen-free PP gray [600] |
| Conductor structure signal line | 32x 0.10 mm |
| AWG signal line | 24 |
| Conductor cross section | 4x 0.25 mm² (Signal line) |
| Wire diameter incl. insulation | 1.17 mm ±0.02 mm (Signal line) |
| External cable diameter | 4.50 mm ±0.15 mm |
| Outer sheath, material | PP-EPDM |
| External sheath, color | gray RAL 7035 |
| Conductor material | Bare Cu litz wires |
| Material wire insulation | PP |
| Single wire, color | brown, white, blue, black |
| Thickness, insulation | ≥ 0.21 mm (Core insulation) |
| Thickness, outer sheath | approx. 0.80 mm |
| Overall twist | 4 wires, twisted |
| Length of twist, overall twist | 44 mm |
| Max. conductor resistance | 78 Ω/km (at 20 °C) |
| Insulation resistance | ≥ 1 GΩ*km (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V AC |
| Test voltage | ≥ 3000 V AC (Spark test) |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, fixed installation | 23 mm |
| Smallest bending radius, movable installation | 45 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 10 x D, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² |
| Dynamic load capacity (torsion) | Torsion: ±270 °/m, Torsion cycles: ≥4000000, Torsional frequency: max.25 Torsion cycles/min |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Other resistance | Resistant to cold bending and cold impacts (according to DIN EN 60811-1-4 (-40 °C)) |
| Special properties | FDA compliant according to FDA 21 CFR 177.2600 |
| highly flexible | |
| Flexible cable conduit capable | |
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
| -25 °C ... 105 °C (Cable, flexible installation) | |